Programming an RTR Endpoint to the Odometer Setting

To install an ORION endpoint on an active meter with usage on an RTR, use the following information to ensure that the value

in the endpoint matches the current odometer value on the RTR once the endpoint is connected to the RTR
With an RTR, you must also program and set the endpoint to the RTR odometer value following a tamper repair

OTEE:

N

An ORION endpoint connected to an ADE, E-LCD or approved competitive three-wire encoder or an ADE or High

Resolution E-Series Ultrasonic meter does not require programming to clear a tamper After the wires have been

repaired, the endpoint is automatically updated to reflect the register odometer value in the first hour after the wires

have been repaired

MPORTANT

I

Stopping an endpoint suspends data profiling. Restarting clears all historical interval data (profile data) and places fixed

mode endpoints into mobile mode. Endpoints in mobile mode may not revert to fixed mode for up to 48 hours.

Reading the Odometer

To install an ORION Migratable endpoint on an active meter with usage on the RTR, use the following information to ensure

that the value in the endpoint matches the current odometer value on the RTR once the endpoint is connected to the RTR

When programming ORION endpoints, enter the value of the six

moveable odometer wheels plus the sweep hand for all meter types

(gallons, cubic feet, etc ) and all meter models
In the example shown, the odometer value in the moveable dials

(both white and black digits) is ”000001 “
The sweep hand is pointing between the ”6“ and the “7“ but because

the sweep hand has not yet hit the ”7“, use ”6“ as the value for the last

digit of the meter reading In this example, the value to be entered

into the ORION endpoint Current Reading field would be ”16“or

”0000016 “ (The leading zeros are not required )

Figure 20: RTR odometer

When programming an ORION endpoint connected to an E-Series

meter with an RTR protocol, program the seven most significant (left

most) digits shown on the meter display

Figure 21: E-Series meter display

IR PROGRAMMING

Page 23

April 2014