5 selecting judgment result output and bcd output – SHIMPO DEG-2000 User Manual
Page 25

23
7.3.5 Selecting judgment result output and BCD output
Number
1
2
3
4
5
6
Parallel Parallel Parallel Parallel
Code
Output type
OK 3 or
less
OK 7 or
less
OK 16 or
less
OK 39 or
less
OK 99 or less
BCD
All items
–
–
–
–
–
–
Each
item
–
–
Output
items
Items 1
and 2
–
–
–
–
–
–
External
input/output type
All
All
All
DC
DC
Other
than
those
shown at
left
BC
–
Item 1
Item 2
Item
Item
Item
Item
–
Setup
item
name
–
Rank n
Rank n
Rank n
Rank n
Rank n
–
Setup of
number
of ranks Setup
descrip-
tion
–
7 or less
16 or
less
39 or
less
40 or
more
17 or
more
–
Output item
change by input
signal
No
No
Yes
Yes
Yes
Yes
Yes
Remarks
Refer to
24 page
Refer to
25 page
Refer to
26 page
Refer to
27 page
Refer to
28 page
Refer to
28 page
Refer to
29 page
1. Output type selection
• The output types marked by are normally usable, and the other output types are
options.
• The output types marked by call for addition of a circuit board.
• Numbers 4 and 6 cannot be selected at the same time.
2. Output item change
• The settings of output items 1 to 5 can be changed with [JUDG OUT] in the set mode.
• The setting of output item 6 can be changed with [BCD OUT] in the set mode.
• When one of Items 1 to 3 is selected as output item, an item bit can be entered to
temporarily change the output item among Items 1 to 3. When the item bit is not
entered, the data of the set output item is output.
*In the case of BCD output, enter a BCD item bit instead of an item bit.