KYORITSU 5020 Instruction Manual User Manual
Page 15

̶
12
̶
4. Can make measurement right after
powering on the instrument.
* Each time pressing the
button,
CH1 to CH3 switches. When
(non-connect) is displayed on the
LCD, a sensor is not connected
to the selected channel; or the
connection is incorrect.
Check the mark indicating the selected
recording mode. Refer to “5. Recording
modes and conditions” in this manual
to change the recording mode or
condition (Recording interval / Preset
current)
Recording mode
Details
Refer to
Normal
Performs continuous measurement/
recording at the pre-set intervals.
(15-kind: 1 sec. to 60min.)
P.19
Trigger
Records 8 data (0.8 sec.) in total with
time information when pre-set detection
level is exceeded.
P.22
Capture
Records 10 (50Hz) to 12 waveforms
(60Hz) when preset detection level is
exceeded.
(Graph can be viewed on PC)
P.24
(PC setting)
Power Quality Analysis
(only 5020)
Records date and time information when
preset Swell, Dip and Short interruption
value are exceeded.
P.24
(PC setting)
Step2: Confirmation of preset value