API: Density standard type

When the correction type is 1 (Standard volume/mass by API2540):

The type of density standard (at temperature and pressure standard)

0: Fill in manually

1: Calculated from process density ((measured by densito meter)

2: On AD/Modbus input


API: Fluid type

When the correction type is 1 (Standard volume/mass by API2540):

The type of fluid:

0: Crude

1:

Gasoline

2: Trans.area

3: Jet group

4: Fuel oil

5: Free fill


API: Stand. Density crude/gasoline/trans.area/jetgroup/fuel oil/free fill
When the correction type is 1 (Standard volume/mass by API2540):

Limits for 15°C standard

Crude

:

610.5..1075.0 kg/m3

Gasoline

:

653.0.. 770.0 kg/m3

Trans.area

:

770.5.. 787.5 kg/m3

Jet group

:

788.0.. 838.5 kg/m3

Fuel oil

:

839.0..1075.0 kg/m3

free fill

:

500.0..2000.0 kg/m3

When a value is outside the limits the UFP-V system will not accept the value


API: Free Fill K0/1/2

When the correction type is 1 (Standard volume/mass by API2540) and Fluid type is 5 (free fill):

K0…K2 are factors used in the API calculation.

Limits are –10

e

9 .. 10

e

9


API: Temperature standard

When the correction type is 1 (Standard volume/mass by API2540):

The standard temperature is the temperature at standard conditions.

Limits are 0..30°C


Batch averages 1 on temperatures, pressures, densities, and correction factors

On reset Totalisers (or Boolean set to 1 only) new batch averages are made for a maximum of 1500

days, after 1500 days the averages are no longer calculated.

Batch averages 2 on temperatures, pressures, densities, and correction factors

Boolean set to 1 only new batch averages are made for a maximum of 1500 days, after 1500 days the

averages are no longer calculated.