KROHNE ALTOSONIC V Modbus EN User Manual
Page 36
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 36 of 64
27
I16+R
System messages 01..16
5
1
[ ]
28
I16+R
System messages 17..32
5
1
[ ]
29
I16+R
System messages 33..48
5
1
[ ]
30
I16+R
System messages 49..64
5
1
[ ]
31
I16+R
Number of current warnings
1
2
3
[ ] Applicable to all levels
32
I16+R
Number of current alarms
1
2
3
[ ] Applicable to all levels
33
I16+R
SYSTEM TIME: seconds
2
0…59
34
I16+R
SYSTEM TIME: minutes
2
0…59
35
I16+R
SYSTEM TIME: hours
2
0…23
36
I16+R
SYSTEM TIME: day
2
1…31
37
I16+R
SYSTEM TIME: month
2
1…12
38
I16+R
SYSTEM TIME: year
2
2001…
39
I16+R
MP103 FreqOutp. Flow_direction
7
0=fwd, 1=fwd&rev
40
I16+R
MP103 FreqOutp. Frequency_mode
7
see clnt0300.dat file
41
I16+R
Number of values in use (FIFO) for Gross Flow Average
5
[ ]
42
I16+R
Last Batch Result Status Bits (7 LSB)
4
[ ]
43
I16+R
Batch start: Resetable Totaliser Fract. (sum)
4
1
0.xxxx m3
44
I16+R
Batch start: Resetable Totaliser Fract. (fwd)
4
1
0.xxxx m3
45
I16+R
Batch start: Resetable Totaliser Fract. (rev)
4
1
0.xxxx m3
46
I16+R
Batch start: Resetable Standard Totaliser Fract. (sum)
4
2
0.xxxx m3
47
I16+R
Batch start: Resetable Standard Totaliser Fract. (fwd)
4
2
0.xxxx m3
48
I16+R
Batch start: Resetable Standard Totaliser Fract. (rev)
4
2
0.xxxx m3
49
I16+R
Batch start: Resetable Mass Totaliser Fract. (sum)
4
2
0.xxxx ton
50
I16+R
Batch start: Resetable Mass Totaliser Fract. (fwd)
4
2
0.xxxx ton
51
I16+R
Batch start: Resetable Mass Totaliser Fract. (rev)
4
2
0.xxxx ton
52
I16+R
Batch start: Resetable Ext. Standard Totaliser Fract.
(sum)
4
8
0.xxxx m3
53
I16+R
Batch start: Resetable Ext. Standard Totaliser Fract. (fwd)
4
8
0.xxxx m3
54
I16+R
Batch start: Resetable Ext. Standard Totaliser Fract. (rev)
4
8
0.xxxx m3
55
I16+R
Batch start: NonResetable Totaliser Fract. (sum)
4
1
0.xxxx m3
56
I16+R
Batch start: NonResetable Totaliser Fract. (fwd)
4
1
0.xxxx m3
57
I16+R
Batch start: NonResetable Totaliser Fract. (rev)
4
1
0.xxxx m3
58
I16+R
Batch start: NonResetable Standard Totaliser Fract.
(sum)
4
2
0.xxxx m3
59
I16+R
Batch start: NonResetable Standard Totaliser Fract. (fwd)
4
2
0.xxxx m3
60
I16+R
Batch start: NonResetable Standard Totaliser Fract. (rev)
4
2
0.xxxx m3
61
I16+R
Batch start: NonResetable Mass Totaliser Fract. (sum)
4
2
0.xxxx ton
62
I16+R
Batch start: NonResetable Mass Totaliser Fract. (fwd)
4
2
0.xxxx ton
63
I16+R
Batch start: NonResetable Mass Totaliser Fract. (rev)
4
2
0.xxxx ton
64
I16+R
Batch stop: Resetable Totaliser Fract. (sum)
4
1
0.xxxx m3
65
I16+R
Batch stop: Resetable Totaliser Fract. (fwd)
4
1
0.xxxx m3
66
I16+R
Batch stop: Resetable Totaliser Fract. (rev)
4
1
0.xxxx m3
67
I16+R
Batch stop: Resetable Standard Totaliser Fract. (sum)
4
2
0.xxxx m3
68
I16+R
Batch stop: Resetable Standard Totaliser Fract. (fwd)
4
2
0.xxxx m3
69
I16+R
Batch stop: Resetable Standard Totaliser Fract. (rev)
4
2
0.xxxx m3
70
I16+R
Batch stop: Resetable Mass Totaliser Fract. (sum)
4
2
0.xxxx ton
71
I16+R
Batch stop: Resetable Mass Totaliser Fract. (fwd)
4
2
0.xxxx ton
72
I16+R
Batch stop: Resetable Mass Totaliser Fract. (rev)
4
2
0.xxxx ton
73
I16+R
Batch stop: Resetable Ext. Standard Totaliser Fract.
(sum)
4
8
0.xxxx m3
74
I16+R
Batch stop: Resetable Ext. Standard Totaliser Fract. (fwd)
4
8
0.xxxx m3
75
I16+R
Batch stop: Resetable Ext. Standard Totaliser Fract. (rev)
4
8
0.xxxx m3
76
I16+R
Batch stop: NonResetable Totaliser Fract. (sum)
4
1
0.xxxx m3
77
I16+R
Batch stop: NonResetable Totaliser Fract. (fwd)
4
1
0.xxxx m3
78
I16+R
Batch stop: NonResetable Totaliser Fract. (rev)
4
1
0.xxxx m3