KROHNE ALTOSONIC V Modbus EN User Manual
Page 40
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 40 of 64
94
187
I32+R
CRC for UFS files
1
[ ]
95
189
I32+R
CRC for UFP files
1
[ ]
96
191
I32+R
CRC for DAT files
1
[ ]
97
193
I32+R
CRC for (last) Ticket
1
[ ]
98
195
I32+R
CRC for Executable (program)
1
[ ]
99
197
I32+R
Serial number xxxxxxyyyy, project number x ( 6 or 7 digits )
1
[ ]
100
199
I32+R
Serial number xxxxxxyyyy, part number y (4 digits always)
1
[ ]
8.5
Field 4 (Read only Float Field)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave
mode and with functions 6 and 16 in Modbus master mode.
By default the start addresses are mapped to address 7000 (default value)
s
ta
rt
a
d
d
re
s
s
N
o
tM
o
d
ic
o
n
C
o
m
p
s
ta
rt
a
d
d
re
s
s
M
o
d
ic
o
n
C
o
m
p
T
y
p
e
+
A
c
c
e
s
s
D
e
s
c
ri
p
ti
o
n
Le
ve
l
Le
ve
l
Le
ve
l
R
e
m
a
rk
1
1
F32+R
Flow process
1
m
3
/hr
2
3
F32+R
Sound velocity average
1
m/s
3
5
F32+R
Temperature process
2
°C
4
7
F32+R
Pressure process
1
2
bar
5
9
F32+R
Density process
1
kg/m
3
6
11
F32+R
Temperature body
1
°C
7
13
F32+R
Flow standard
2
m
3
/hr
8
15
F32+R
Flow mass
2
ton/hr
9
17
F32+R
raw UFCdata Flow channel 1
5
1
-1250…1250
10
19
F32+R
raw UFCdata Flow channel 2
5
1
-1250…1250
11
21
F32+R
raw UFCdata Flow channel 3
5
1
-1250…1250
12
23
F32+R
raw UFCdata Flow channel 4
5
1
-1250…1250
13
25
F32+R
raw UFCdata Flow channel 5
5
1
-1250…1250
14
27
F32+R
Sound velocity of path 1
5
1
m/s
15
29
F32+R
Sound velocity of path 2
5
1
m/s
16
31
F32+R
Sound velocity of path 3
5
1
m/s
17
33
F32+R
Sound velocity of path 4
5
1
m/s
18
35
F32+R
Sound velocity of path 5
5
1
m/s
19
37
F32+R
Remaining hold time on correction. Due to flow deviation
5
1
m/s
20
39
F32+R
Reynolds number
5
1
[ ]
21
41
F32+R
Swirl % profile diagnostics
5
1
%
22
43
F32+R
Viscosity internal
5
1
cSt or 10
-6
m
2
/s
23
45
F32+R
A
5
1
[ ]
24
47
F32+R
B
5
1
[ ]
25
49
F32+R
A_offset
5
1
[ ]
26
51
F32+R
B_offset
5
1
[ ]
27
53
F32+R
Kr
5
1
[ ]
28
55
F32+R
Ks
5
1
[ ]
29
57
F32+R
Skewness % profile diagnostics
5
1
%
30
59
F32+R
Kbp Pressure Body expansion correction factor
1
[ ]
31
61
F32+R
Kb Thermal Body expansion correction factor
1
[ ]
32
63
F32+R
Density standard
2
kg/m
3
33
65
F32+R
Krohne use only