KROHNE ALTOSONIC V Modbus EN User Manual
Page 41
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 41 of 64
34
67
F32+R
Krohne use only
35
69
F32+R
Krohne use only
36
71
F32+R
Krohne use only
37
73
F32+R
Krohne use only
38
75
F32+R
Remaining hold time on real-profile sampling. By flow deviation
5
1
s
39
77
F32+R
Average by stdev: raw UFCdata Flow channel 1
5
1
0 to 1000
40
79
F32+R
Average by stdev: raw UFCdata Flow channel 2
5
1
0 to 1000
41
81
F32+R
Average by stdev: raw UFCdata Flow channel 3
5
1
0 to 1000
42
83
F32+R
Average by stdev: raw UFCdata Flow channel 4
5
1
0 to 1000
43
85
F32+R
Average by stdev: raw UFCdata Flow channel 5
5
1
0 to 1000
44
87
F32+R
Viscosity external (default not used)
1
cSt or 10-6 m2/s
45
89
F32+R
Temperature densitometer
2
°C
46
91
F32+R
Pressure densitometer
2
bar
47
93
F32+R
Temperature proving (external flowmeter)
8
°C
48
95
F32+R
Pressure proving (external flowmeter)
8
bar
49
97
F32+R
stdev: raw UFCdata Flow channel 1
5
1
%'
50
99
F32+R
stdev: raw UFCdata Flow channel 2
5
1
%'
51
101
F32+R
stdev: raw UFCdata Flow channel 3
5
1
%'
52
103
F32+R
stdev: raw UFCdata Flow channel 4
5
1
%'
53
105
F32+R
stdev: raw UFCdata Flow channel 5
5
1
%'
54
107
F32+R
Standard deviation of flow
5
1
%'
55
109
F32+R
Max deviation on tau2::tau2/10 for correction path 1
5
1
%'
56
111
F32+R
Max deviation on tau2::tau2/10 for correction path 2
5
1
%'
57
113
F32+R
Max deviation on tau2::tau2/10 for correction path 3
5
1
%'
58
115
F32+R
Max deviation on tau2::tau2/10 for correction path 4
5
1
%'
59
117
F32+R
Max deviation on tau2::tau2/10 for correction path 5
5
1
%'
60
119
F32+R
Max deviation on tau2::tau2/10 for correction flow
5
1
%'
61
121
F32+R
Max deviation on treal::treal/10 for profile measure path 1
5
1
%'
62
123
F32+R
Max deviation on treal::treal/10 for profile measure path 2
5
1
%'
63
125
F32+R
Max deviation on treal::treal/10 for profile measure path 3
5
1
%'
64
127
F32+R
Max deviation on treal::treal/10 for profile measure path 4
5
1
%'
65
129
F32+R
Max deviation on treal::treal/10 for profile measure path 5
5
1
%'
66
131
F32+R
Max deviation on treal::treal/10 for profile measure
5
1
%'
67
133
F32+R
Density densitometer
2
kg/m3
68
135
F32+R
Maximum flow rate
7
m3/h
69
137
F32+R
Ctl (15°C to process)
2
[ ]
70
139
F32+R
Cpl (0 bar to process)
2
[ ]
71
141
F32+R
Ctl (15°C to standard)
2
[ ]
72
143
F32+R
Cpl (0 bar to standard. always 1)
2
[ ]
73
145
F32+R
Ctl (15°C to densitometer)
2
[ ]
74
147
F32+R
Cpl (0 bar to densitometer)
2
[ ]
75
149
F32+R
Ctl (15°C to proving external flowmeter)
2
[ ]
76
151
F32+R
Cpl (0 bar to proving external flowmeter)
2
[ ]
77
153
F32+R
Batch 1 average temperature body
4
1
°C
78
155
F32+R
Batch 1 average temperature process
4
2
°C
79
157
F32+R
Batch 1 average temperature proving (external flowmeter)
4
8
°C
80
159
F32+R
Batch 1 average temperature densitometer
4
2
°C
81
161
F32+R
Batch 1 average pressure process
4
1
2
bar
82
163
F32+R
Batch 1 average pressure proving (external flowmeter)
4
8
bar
83
165
F32+R
Batch 1 average pressure densitimeter
4
2
bar
84
167
F32+R
Batch 1 average density densitometer
4
2
kg/m3
85
169
F32+R
Batch 1 average density standard
4
2
kg/m3
86
171
F32+R
Batch 1 avarage BS&W in percent
4
3
%