ALTOSONIC V

ModBus Manual 0300 rev07 E

7.30855.35.00

Page 21 of 64

7.2.1

RS485/422 card: AX4285A

The first generation of RS 485 cards used

DIP SWITCH CH1***

: COM 3 Baseaddress ch#1: 3E8

DIP SWITCH CH2***

: COM 4 Baseaddress ch#2: 2E8

JP1***

: COM3 Interrupt IRQ4

JP2***

: COM4 Interrupt IRQ3

JP3***

: COM3 RS 485 mode

JP4***

: COM3 Serial resistors enabled, No jumpers installed

JP5

: COM4 RS 485 mode as default

JP6

: COM4 Serial resistors not enabled, jumpers installed


***(=Krohne Altometer setting)
NOTE:
RS485 mode and RS422 mode for COM4 (Modbus) differs in set-up by:
-

Jumper JP5 RS485 or RS422

-

The external wiring for RS422 and RS485

External wiring AX5285A for Modbus:

The resistors of 120 Ohm must be placed at the Altosonic-V wiring terminal