KROHNE ALTOSONIC V Modbus EN User Manual
Page 31
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 31 of 64
77
B+R
OVERRIDE enable possible for pressure proving (ext flowm)
8
7
78
B+R
OVERRIDE enable possible for pressure densitometer
2
7
79
B+R
OVERRIDE enable possible for density densitometer
2
7
80
B+R
OVERRIDE enable possible for density standard
2
7
81
B+R
OVERRIDE enable possible for viscosity external
1
7
82
B+R
OVERRIDE default (automatic) temperature body
1
5
if enabled in CLNT0300.dat
83
B+R
OVERRIDE default (automatic) temperature process
2
5
if enabled in CLNT0300.dat
84
B+R
OVERRIDE default (automatic) temperature proving (ext flowm)
8
5
if enabled in CLNT0300.dat
85
B+R
OVERRIDE default (automatic) temperature densitometer
2
5
if enabled in CLNT0300.dat
86
B+R
OVERRIDE default (automatic) pressure process
2
5
if enabled in CLNT0300.dat
87
B+R
OVERRIDE default (automatic) pressure proving (ext flowm)
8
5
if enabled in CLNT0300.dat
88
B+R
OVERRIDE default (automatic) pressure densitometer
2
5
if enabled in CLNT0300.dat
89
B+R
OVERRIDE default (automatic) density densitometer
2
5
if enabled in CLNT0300.dat
90
B+R
OVERRIDE default (automatic) density standard
2
5
if enabled in CLNT0300.dat
91
B+R
OVERRIDE default (automatic) viscosity external
1
5
if enabled in CLNT0300.dat
92
B+R
Batch valid. on last stopped batch (no mem after program stop)
4
0=not valid 1=valid
93
B+R
Alarm on Reynolds value: outside of the allowed range
1
5
94
B+R
OVERRIDE enable possible for BS&W percentage
3
7
95
B+R
OVERRIDE default (automatic) BS&W percentage
3
5
if enabled in CLNT0300.dat
96
B+R
Alarm on reading: BS&W percentage
3
5
97
B+R
Alarm on service value: BS&W percentage
9
3
8.2
Field 1 (Read/Write Boolean Field)
These data can be accessed with Modbus function 1, 2, 5 and 15.
Without further notice 0=non and 1=active
By default the start addresses are mapped to address 2000 (default value)
s
ta
rt
a
d
d
re
s
s
M
o
d
ic
o
n
C
o
m
p
N
o
tM
o
d
ic
o
n
C
o
m
p
T
y
p
e
+
A
c
c
e
s
s
D
e
s
c
ri
p
ti
o
n
Le
ve
l
Le
ve
l
Le
ve
l
R
e
m
a
rk
1
B+RW
Acknowledge_flags_field_00
6
5
2
B+RW
Acknowledge_flags_field_01
6
5
3
B+RW
Acknowledge_flags_field_02
6
5
4
B+RW
Acknowledge_flags_field_03
6
5
5
B+RW
Acknowledge_flags_field_04
6
5
6
B+RW
Acknowledge_flags_field_05
6
5
7
B+RW
Acknowledge_flags_field_06
6
5
8
B+RW
Acknowledge_flags_field_07
6
5
9
B+RW
Acknowledge_flags_field_08
6
5
10
B+RW
Acknowledge_flags_field_09
6
5
11
B+RW
Acknowledge_flags_field_00
6
5
12
B+RW
Acknowledge_flags_field_11
6
5
13
B+RW
Acknowledge_flags_field_12
6
5
14
B+RW
Acknowledge_flags_field_13
6
5
15
B+RW
Acknowledge_flags_field_14
6
5
16
B+RW
Acknowledge_flags_field_15
6
5
17
B+RW
Acknowledge_flags_field_16
6
5
18
B+RW
Acknowledge_flags_field_17
6
5