beautypg.com

KROHNE ALTOSONIC V Modbus EN User Manual

Page 39

background image

ALTOSONIC V

ModBus Manual 0300 rev07 E

7.30855.35.00

Page 39 of 64

41

81

I32+R

Resetable totaliser: mass forward (nett.oil)

3

kg

42

83

I32+R

Resetable totaliser: mass reverse (nett.oil)

3

kg

43

85

I32+R

Non resetable totaliser: process sum (nett.oil)

3

liter

44

87

I32+R

Non resetable totaliser: process forward (nett.oil)

3

liter

45

89

I32+R

Non resetable totaliser: process reverse (nett.oil)

3

liter

46

91

I32+R

Non resetable totaliser: standard sum (nett.oil)

3

liter

47

93

I32+R

Non resetable totaliser: standard forward (nett.oil)

3

liter

48

95

I32+R

Non resetable totaliser: standard reverse (nett.oil)

3

liter

49

97

I32+R

Non resetable totaliser: mass sum (nett.oil)

3

kg

50

99

I32+R

Non resetable totaliser: mass forward (nett.oil)

3

kg

51

101

I32+R

Non resetable totaliser: mass reverse (nett.oil)

3

kg

52

103

I32+R

Batch start: Resetable Totaliser (sum)

4

1

m3, fraction see Int16 reg

53

105

I32+R

Batch start: Resetable Totaliser (forward)

4

1

m3, fraction see Int16 reg

54

107

I32+R

Batch start: Resetable Totaliser (reverse)

4

1

m3, fraction see Int16 reg

55

109

I32+R

Batch start: Resetable Standard Totaliser (sum)

4

2

m3, fraction see Int16 reg

56

111

I32+R

Batch start: Resetable Standard Totaliser (forward)

4

2

m3, fraction see Int16 reg

57

113

I32+R

Batch start: Resetable Standard Totaliser (reverse)

4

2

m3, fraction see Int16 reg

58

115

I32+R

Batch start: Resetable Mass Totaliser (sum)

4

2

ton, fraction see Int16 reg

59

117

I32+R

Batch start: Resetable Mass Totaliser (forward)

4

2

ton, fraction see Int16 reg

60

119

I32+R

Batch start: Resetable Mass Totaliser (reverse)

4

2

ton, fraction see Int16 reg

61

121

I32+R

Batch start: Extern. Resetable Standard Totaliser (sum)

4

8

m3, fraction see Int16 reg

62

123

I32+R

Batch start: Extern. Resetable Standard Totaliser (forward)

4

8

m3, fraction see Int16 reg

63

125

I32+R

Batch start: Extern. Resetable Standard Totaliser (reverse)

4

8

m3, fraction see Int16 reg

64

127

I32+R

Batch start: NonResetable Totaliser (sum)

4

1

m3, fraction see Int16 reg

65

129

I32+R

Batch start: NonResetable Totaliser (forward)

4

1

m3, fraction see Int16 reg

66

131

I32+R

Batch start: NonResetable Totaliser (reverse)

4

1

m3, fraction see Int16 reg

67

133

I32+R

Batch start: NonResetable Standard Totaliser (sum)

4

2

m3, fraction see Int16 reg

68

135

I32+R

Batch start: NonResetable Standard Totaliser (forward)

4

2

m3, fraction see Int16 reg

69

137

I32+R

Batch start: NonResetable Standard Totaliser (reverse)

4

2

m3, fraction see Int16 reg

70

139

I32+R

Batch start: NonResetable Mass Totaliser (sum)

4

2

ton, fraction see Int16 reg

71

141

I32+R

Batch start: NonResetable Mass Totaliser (forward)

4

2

ton, fraction see Int16 reg

72

143

I32+R

Batch start: NonResetable Mass Totaliser (reverse)

4

2

ton, fraction see Int16 reg

73

145

I32+R

Batch stop: Resetable Totaliser (sum)

4

1

m3, fraction see Int16 reg

74

147

I32+R

Batch stop: Resetable Totaliser (forward)

4

1

m3, fraction see Int16 reg

75

149

I32+R

Batch stop: Resetable Totaliser (reverse)

4

1

m3, fraction see Int16 reg

76

151

I32+R

Batch stop: Resetable Standard Totaliser (sum)

4

2

m3, fraction see Int16 reg

77

153

I32+R

Batch stop: Resetable Standard Totaliser (forward)

4

2

m3, fraction see Int16 reg

78

155

I32+R

Batch stop: Resetable Standard Totaliser (reverse)

4

2

m3, fraction see Int16 reg

79

157

I32+R

Batch stop: Resetable Mass Totaliser (sum)

4

2

ton, fraction see Int16 reg

80

159

I32+R

Batch stop: Resetable Mass Totaliser (forward)

4

2

ton, fraction see Int16 reg

81

161

I32+R

Batch stop: Resetable Mass Totaliser (reverse)

4

2

ton, fraction see Int16 reg

82

163

I32+R

Batch stop: Extern. Resetable Standard Totaliser (sum)

4

8

m3, fraction see Int16 reg

83

165

I32+R

Batch stop: Extern. Resetable Standard Totaliser (forward)

4

8

m3, fraction see Int16 reg

84

167

I32+R

Batch stop: Extern. Resetable Standard Totaliser (reverse)

4

8

m3, fraction see Int16 reg

85

169

I32+R

Batch stop: NonResetable Totaliser (sum)

4

1

m3, fraction see Int16 reg

86

171

I32+R

Batch stop: NonResetable Totaliser (forward)

4

1

m3, fraction see Int16 reg

87

173

I32+R

Batch stop: NonResetable Totaliser (reverse)

4

1

m3, fraction see Int16 reg

88

175

I32+R

Batch stop: NonResetable Standard Totaliser (sum)

4

2

m3, fraction see Int16 reg

89

177

I32+R

Batch stop: NonResetable Standard Totaliser (forward)

4

2

m3, fraction see Int16 reg

90

179

I32+R

Batch stop: NonResetable Standard Totaliser (reverse)

4

2

m3, fraction see Int16 reg

91

181

I32+R

Batch stop: NonResetable Mass Totaliser (sum)

4

2

ton, fraction see Int16 reg

92

183

I32+R

Batch stop: NonResetable Mass Totaliser (forward)

4

2

ton, fraction see Int16 reg

93

185

I32+R

Batch stop: NonResetable Mass Totaliser (reverse)

4

2

ton, fraction see Int16 reg