KROHNE ALTOSONIC V Modbus EN User Manual
Page 39
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 39 of 64
41
81
I32+R
Resetable totaliser: mass forward (nett.oil)
3
kg
42
83
I32+R
Resetable totaliser: mass reverse (nett.oil)
3
kg
43
85
I32+R
Non resetable totaliser: process sum (nett.oil)
3
liter
44
87
I32+R
Non resetable totaliser: process forward (nett.oil)
3
liter
45
89
I32+R
Non resetable totaliser: process reverse (nett.oil)
3
liter
46
91
I32+R
Non resetable totaliser: standard sum (nett.oil)
3
liter
47
93
I32+R
Non resetable totaliser: standard forward (nett.oil)
3
liter
48
95
I32+R
Non resetable totaliser: standard reverse (nett.oil)
3
liter
49
97
I32+R
Non resetable totaliser: mass sum (nett.oil)
3
kg
50
99
I32+R
Non resetable totaliser: mass forward (nett.oil)
3
kg
51
101
I32+R
Non resetable totaliser: mass reverse (nett.oil)
3
kg
52
103
I32+R
Batch start: Resetable Totaliser (sum)
4
1
m3, fraction see Int16 reg
53
105
I32+R
Batch start: Resetable Totaliser (forward)
4
1
m3, fraction see Int16 reg
54
107
I32+R
Batch start: Resetable Totaliser (reverse)
4
1
m3, fraction see Int16 reg
55
109
I32+R
Batch start: Resetable Standard Totaliser (sum)
4
2
m3, fraction see Int16 reg
56
111
I32+R
Batch start: Resetable Standard Totaliser (forward)
4
2
m3, fraction see Int16 reg
57
113
I32+R
Batch start: Resetable Standard Totaliser (reverse)
4
2
m3, fraction see Int16 reg
58
115
I32+R
Batch start: Resetable Mass Totaliser (sum)
4
2
ton, fraction see Int16 reg
59
117
I32+R
Batch start: Resetable Mass Totaliser (forward)
4
2
ton, fraction see Int16 reg
60
119
I32+R
Batch start: Resetable Mass Totaliser (reverse)
4
2
ton, fraction see Int16 reg
61
121
I32+R
Batch start: Extern. Resetable Standard Totaliser (sum)
4
8
m3, fraction see Int16 reg
62
123
I32+R
Batch start: Extern. Resetable Standard Totaliser (forward)
4
8
m3, fraction see Int16 reg
63
125
I32+R
Batch start: Extern. Resetable Standard Totaliser (reverse)
4
8
m3, fraction see Int16 reg
64
127
I32+R
Batch start: NonResetable Totaliser (sum)
4
1
m3, fraction see Int16 reg
65
129
I32+R
Batch start: NonResetable Totaliser (forward)
4
1
m3, fraction see Int16 reg
66
131
I32+R
Batch start: NonResetable Totaliser (reverse)
4
1
m3, fraction see Int16 reg
67
133
I32+R
Batch start: NonResetable Standard Totaliser (sum)
4
2
m3, fraction see Int16 reg
68
135
I32+R
Batch start: NonResetable Standard Totaliser (forward)
4
2
m3, fraction see Int16 reg
69
137
I32+R
Batch start: NonResetable Standard Totaliser (reverse)
4
2
m3, fraction see Int16 reg
70
139
I32+R
Batch start: NonResetable Mass Totaliser (sum)
4
2
ton, fraction see Int16 reg
71
141
I32+R
Batch start: NonResetable Mass Totaliser (forward)
4
2
ton, fraction see Int16 reg
72
143
I32+R
Batch start: NonResetable Mass Totaliser (reverse)
4
2
ton, fraction see Int16 reg
73
145
I32+R
Batch stop: Resetable Totaliser (sum)
4
1
m3, fraction see Int16 reg
74
147
I32+R
Batch stop: Resetable Totaliser (forward)
4
1
m3, fraction see Int16 reg
75
149
I32+R
Batch stop: Resetable Totaliser (reverse)
4
1
m3, fraction see Int16 reg
76
151
I32+R
Batch stop: Resetable Standard Totaliser (sum)
4
2
m3, fraction see Int16 reg
77
153
I32+R
Batch stop: Resetable Standard Totaliser (forward)
4
2
m3, fraction see Int16 reg
78
155
I32+R
Batch stop: Resetable Standard Totaliser (reverse)
4
2
m3, fraction see Int16 reg
79
157
I32+R
Batch stop: Resetable Mass Totaliser (sum)
4
2
ton, fraction see Int16 reg
80
159
I32+R
Batch stop: Resetable Mass Totaliser (forward)
4
2
ton, fraction see Int16 reg
81
161
I32+R
Batch stop: Resetable Mass Totaliser (reverse)
4
2
ton, fraction see Int16 reg
82
163
I32+R
Batch stop: Extern. Resetable Standard Totaliser (sum)
4
8
m3, fraction see Int16 reg
83
165
I32+R
Batch stop: Extern. Resetable Standard Totaliser (forward)
4
8
m3, fraction see Int16 reg
84
167
I32+R
Batch stop: Extern. Resetable Standard Totaliser (reverse)
4
8
m3, fraction see Int16 reg
85
169
I32+R
Batch stop: NonResetable Totaliser (sum)
4
1
m3, fraction see Int16 reg
86
171
I32+R
Batch stop: NonResetable Totaliser (forward)
4
1
m3, fraction see Int16 reg
87
173
I32+R
Batch stop: NonResetable Totaliser (reverse)
4
1
m3, fraction see Int16 reg
88
175
I32+R
Batch stop: NonResetable Standard Totaliser (sum)
4
2
m3, fraction see Int16 reg
89
177
I32+R
Batch stop: NonResetable Standard Totaliser (forward)
4
2
m3, fraction see Int16 reg
90
179
I32+R
Batch stop: NonResetable Standard Totaliser (reverse)
4
2
m3, fraction see Int16 reg
91
181
I32+R
Batch stop: NonResetable Mass Totaliser (sum)
4
2
ton, fraction see Int16 reg
92
183
I32+R
Batch stop: NonResetable Mass Totaliser (forward)
4
2
ton, fraction see Int16 reg
93
185
I32+R
Batch stop: NonResetable Mass Totaliser (reverse)
4
2
ton, fraction see Int16 reg