KROHNE ALTOSONIC V Modbus EN User Manual

Page 48

background image

ALTOSONIC V

ModBus Manual 0300 rev07 E

7.30855.35.00

Page 48 of 64

72

143

F32+RW

Input in UFP (if enabled): pressure proving. external flowmeter

6

8

bar

73

145

F32+RW

Input in UFP (if enabled): pressure densitometer

6

2

bar

74

147

F32+RW

Input in UFP (if enabled): density densitometer

6

2

kg/m3

75

149

F32+RW

Input in UFP (if enabled): density standard

6

2

kg/m3

76

151

F32+RW

Input in UFP (if enabled): viscosity dynamic

6

1

cSt or 10-6 m2/s

77

153

F32+RW

System time UFP adjustment (see B2230 to enable write)

6

4

-7200…7200 s

78

155

F32+R

OVERRIDE: Time to update a parameter (read only)

5

s, max 30 sec

79

157

F32+RW

OVERRIDE if set is enabled: temperature body to override

6

1

°C

80

159

F32+RW

OVERRIDE if set is enabled: temperature process to override

6

2

°C

81

161

F32+RW

OVERRIDE if set is enabled: temperature proving to override

6

8

°C

82

163

F32+RW

OVERRIDE if set is enabled: temperature densitometer to
override

6

2

°C

83

165

F32+RW

OVERRIDE if set is enabled: pressure process to override

6

1

2

bar

84

167

F32+RW

OVERRIDE if set is enabled: pressure proving to override

6

8

bar

85

169

F32+RW

OVERRIDE if set is enabled: pressure densitometer to override

6

2

bar

86

171

F32+RW

OVERRIDE if set is enabled: density densitometer to override

6

2

kg/m3

87

173

F32+RW

OVERRIDE if set is enabled: density standard to override

6

2

kg/m3

88

175

F32+RW

OVERRIDE if set is enabled: viscosity dynamic to override

6

1

cSt or 10-6 m2/s

89

177

F32+RW

Batch reference number for internal batch ticket

6

4

[ ]

90

179

F32+RW

Krohne use: Calibration volume

[ ]

91

181

F32+R

Input in UFP (if enabled): BS&W Input

6

3

%

92

183

F32+RW

Reserved

93

185

F32+RW

Reserved

94

187

F32+RW

Reserved

95

189

F32+RW

Batch Float Start Value 1 batch ticket print code 750

6

4

To print in the batch ticket

96

191

F32+RW

Batch Float Start Value 2 batch ticket print code 751

6

4

To print in the batch ticket

97

193

F32+RW

Batch Float Start Value 3 batch ticket print code 752

6

4

To print in the batch ticket

98

195

F32+RW

Batch Float Start Value 4 batch ticket print code 753

6

4

To print in the batch ticket

99

197

F32+RW

Batch Float Start Value 5 batch ticket print code 754

6

4

To print in the batch ticket

100

199

F32+RW

Batch Float Stop Value 1 batch ticket print code 755

6

4

To print in the batch ticket

101

201

F32+RW

Batch Float Stop Value 2 batch ticket print code 756

6

4

To print in the batch ticket

102

203

F32+RW

Batch Float Stop Value 3 batch ticket print code 757

6

4

To print in the batch ticket

103

205

F32+RW

Batch Float Stop Value 4 batch ticket print code 758

6

4

To print in the batch ticket

104

207

F32+RW

Batch Float Stop Value 5 batch ticket print code 759

6

4

To print in the batch ticket

105

209

F32+RW

Reserved

106

211

F32+RW

OVERRIDE if set is enabled: BS&W percentage to override

6

3

%

107

213

F32+RW

Set number of values (FIFO) for Gross Flow Running Average.

6

1

2…512

108

215

F32+R

Batch stop: Alarm 1-4 channels down

4

1

5

s

109

217

F32+R

Batch stop: Alarm all channels down

4

1

5

s

110

219

F32+R

Batch stop: Alarm API group mismatch

4

2

5

s

111

221

F32+R

Batch stop: Alarm system runtime

4

2

5

s

112

223

F32+R

Batch stop: Alarm Profile oor

4

1

5

s

113

225

F32+R

Batch stop: Alarm Body Temperature oor

4

1

5

s

114

227

F32+R

Batch stop: Alarm Process Temperature oor

4

1

2

s

115

229

F32+R

Batch stop: Alarm External Temperature oor

4

8

5

s

116

231

F32+R

Batch stop: Alarm Densito Temperature oor

4

2

5

s

117

233

F32+R

Batch stop: Alarm Process Pressure oor

4

2

5

s

118

235

F32+R

Batch stop: Alarm External Pressure oor

4

8

5

s

119

237

F32+R

Batch stop: Alarm Densito Pressure oor

4

2

5

s

120

239

F32+R

Batch stop: Alarm Density oor

4

2

5

s

121

241

F32+R

Batch stop: Alarm Standard Density oor

4

2

5

s

122

243

F32+R

Batch stop: Alarm External Viscosity oor

4

8

5

s

123

245

F32+R

Batch stop: Override Body Temperature

4

1

5

s

124

247

F32+R

Batch stop: Override Process Temperature

4

2

5

s