KROHNE ALTOSONIC V Modbus EN User Manual
Page 48
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 48 of 64
72
143
F32+RW
Input in UFP (if enabled): pressure proving. external flowmeter
6
8
bar
73
145
F32+RW
Input in UFP (if enabled): pressure densitometer
6
2
bar
74
147
F32+RW
Input in UFP (if enabled): density densitometer
6
2
kg/m3
75
149
F32+RW
Input in UFP (if enabled): density standard
6
2
kg/m3
76
151
F32+RW
Input in UFP (if enabled): viscosity dynamic
6
1
cSt or 10-6 m2/s
77
153
F32+RW
System time UFP adjustment (see B2230 to enable write)
6
4
-7200…7200 s
78
155
F32+R
OVERRIDE: Time to update a parameter (read only)
5
s, max 30 sec
79
157
F32+RW
OVERRIDE if set is enabled: temperature body to override
6
1
°C
80
159
F32+RW
OVERRIDE if set is enabled: temperature process to override
6
2
°C
81
161
F32+RW
OVERRIDE if set is enabled: temperature proving to override
6
8
°C
82
163
F32+RW
OVERRIDE if set is enabled: temperature densitometer to
override
6
2
°C
83
165
F32+RW
OVERRIDE if set is enabled: pressure process to override
6
1
2
bar
84
167
F32+RW
OVERRIDE if set is enabled: pressure proving to override
6
8
bar
85
169
F32+RW
OVERRIDE if set is enabled: pressure densitometer to override
6
2
bar
86
171
F32+RW
OVERRIDE if set is enabled: density densitometer to override
6
2
kg/m3
87
173
F32+RW
OVERRIDE if set is enabled: density standard to override
6
2
kg/m3
88
175
F32+RW
OVERRIDE if set is enabled: viscosity dynamic to override
6
1
cSt or 10-6 m2/s
89
177
F32+RW
Batch reference number for internal batch ticket
6
4
[ ]
90
179
F32+RW
Krohne use: Calibration volume
[ ]
91
181
F32+R
Input in UFP (if enabled): BS&W Input
6
3
%
92
183
F32+RW
Reserved
93
185
F32+RW
Reserved
94
187
F32+RW
Reserved
95
189
F32+RW
Batch Float Start Value 1 batch ticket print code 750
6
4
To print in the batch ticket
96
191
F32+RW
Batch Float Start Value 2 batch ticket print code 751
6
4
To print in the batch ticket
97
193
F32+RW
Batch Float Start Value 3 batch ticket print code 752
6
4
To print in the batch ticket
98
195
F32+RW
Batch Float Start Value 4 batch ticket print code 753
6
4
To print in the batch ticket
99
197
F32+RW
Batch Float Start Value 5 batch ticket print code 754
6
4
To print in the batch ticket
100
199
F32+RW
Batch Float Stop Value 1 batch ticket print code 755
6
4
To print in the batch ticket
101
201
F32+RW
Batch Float Stop Value 2 batch ticket print code 756
6
4
To print in the batch ticket
102
203
F32+RW
Batch Float Stop Value 3 batch ticket print code 757
6
4
To print in the batch ticket
103
205
F32+RW
Batch Float Stop Value 4 batch ticket print code 758
6
4
To print in the batch ticket
104
207
F32+RW
Batch Float Stop Value 5 batch ticket print code 759
6
4
To print in the batch ticket
105
209
F32+RW
Reserved
106
211
F32+RW
OVERRIDE if set is enabled: BS&W percentage to override
6
3
%
107
213
F32+RW
Set number of values (FIFO) for Gross Flow Running Average.
6
1
2…512
108
215
F32+R
Batch stop: Alarm 1-4 channels down
4
1
5
s
109
217
F32+R
Batch stop: Alarm all channels down
4
1
5
s
110
219
F32+R
Batch stop: Alarm API group mismatch
4
2
5
s
111
221
F32+R
Batch stop: Alarm system runtime
4
2
5
s
112
223
F32+R
Batch stop: Alarm Profile oor
4
1
5
s
113
225
F32+R
Batch stop: Alarm Body Temperature oor
4
1
5
s
114
227
F32+R
Batch stop: Alarm Process Temperature oor
4
1
2
s
115
229
F32+R
Batch stop: Alarm External Temperature oor
4
8
5
s
116
231
F32+R
Batch stop: Alarm Densito Temperature oor
4
2
5
s
117
233
F32+R
Batch stop: Alarm Process Pressure oor
4
2
5
s
118
235
F32+R
Batch stop: Alarm External Pressure oor
4
8
5
s
119
237
F32+R
Batch stop: Alarm Densito Pressure oor
4
2
5
s
120
239
F32+R
Batch stop: Alarm Density oor
4
2
5
s
121
241
F32+R
Batch stop: Alarm Standard Density oor
4
2
5
s
122
243
F32+R
Batch stop: Alarm External Viscosity oor
4
8
5
s
123
245
F32+R
Batch stop: Override Body Temperature
4
1
5
s
124
247
F32+R
Batch stop: Override Process Temperature
4
2
5
s