KROHNE ALTOSONIC V Modbus EN User Manual
Page 49
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 49 of 64
125
249
F32+R
Batch stop: Override External Temperature
4
8
5
s
126
251
F32+R
Batch stop: Override Density Temperature
4
2
5
s
127
253
F32+R
Batch stop: Override Process Pressure
4
2
5
s
128
255
F32+R
Batch stop: Override External Pressure
4
8
5
s
129
257
F32+R
Batch stop: Override Densito Pressure
4
2
5
s
130
259
F32+R
Batch stop: Override Density
4
2
5
s
131
261
F32+R
Batch stop: Override Standard Density
4
2
5
s
132
263
F32+R
Batch stop: Override External Viscosity
4
1
5
s
133
265
F32+R
Batch stop: Lowest measured Temperature (for high viscosity
applic.)
4
2
5
°C
134
267
F32+R
Batch stop: deviation % (worst case estimate due to batch
alarms)
5
4
%
135
269
F32+R
Batch live: deviation % (worst case estimate due to batch
alarms) during batch
5
4
%
136
271
F32+R
Kinemat.Viscosity - temp corrected - (for ext. visc. input applic.)
1
cSt or 10-6 m2/s
137
273
F32+R
Check Modbus totalisers and batch 1+2 values on hold (see
Bool2075)
4
s, max 30s
8.8
Field 6 (Read Only ASCII Field 8 characters)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and
with functions 6 and 16 in Modbus master mode. This ASCII field is a 64 bit type.
By default the start addresses are mapped to address 4000 (default value)
s
ta
rt
a
d
d
re
s
s
N
o
tM
o
d
ic
o
n
C
o
m
p
s
ta
rt
a
d
d
re
s
s
M
o
d
ic
o
n
C
o
m
p
T
y
p
e
+
A
c
c
e
s
s
D
e
s
c
ri
p
ti
o
n
Le
ve
l
Le
ve
l
Le
ve
l
R
e
m
a
rk
1
1
S32+RW
Ascii32 String Combination of four 8 char
strings for writing one long string to one address
(batch ticket print code 2221 2222 2223 2224)
4
6
To print in the batch ticket
1
1
S8+RW
Ascii8 String 1 (batch ticket print code 2221)
4
6
To print in the batch ticket
2
5
S8+RW
Ascii8 String 2 (batch ticket print code 2222)
4
6
To print in the batch ticket
2
9
S8+RW
Ascii8 String 3 (batch ticket print code 2223)
4
6
To print in the batch ticket
3
13
S8+RW
Ascii8 String 4 (batch ticket print code 2224)
4
6
To print in the batch ticket
8.9
Field 6 (Read Write ASCII Field 16 characters)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and
with functions 6 and 16 in Modbus master mode. This ASCII field is a 128 bit type.
Starting addresses are mapped to address 14000 (default
s
ta
rt
a
d
d
re
s
s
N
o
tM
o
d
ic
o
n
C
o
m
p
s
ta
rt
a
d
d
re
s
s
M
o
d
ic
o
n
C
o
m
p
D
a
ta
T
y
p
e
D
e
s
c
ri
p
ti
o
n
Le
ve
l
Le
ve
l
Le
ve
l
R
e
m
a
rk
1
1
S16+RW
Ascii16 String 5 (batch ticket print code 2261)
4
6
To print in the batch ticket
2
9
S16+RW
Ascii16 String 6 (batch ticket print code 2262)
4
6
To print in the batch ticket
3
17
S16+RW
Ascii16 String 7 (batch ticket print code 2263)
4
6
To print in the batch ticket