KROHNE ALTOSONIC V Modbus EN User Manual
Page 43
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 43 of 64
140
279
F32+R
Batch 2 average Ctl (15°C to standard)
4
2
[ ]
141
281
F32+R
Batch 2 average Cpl (0 bar to standard. always 1)
4
2
[ ]
142
283
F32+R
Batch 2 average Ctl (15°C to densitometer)
4
2
[ ]
143
285
F32+R
Batch 2 average Cpl (0 bar to densitometer)
4
2
[ ]
144
287
F32+R
Batch 2 average Ctl (15°C to proving external flowmeter)
4
8
2
[ ]
145
289
F32+R
Batch 2 average Cpl (0 bar to proving external flowmeter)
4
8
2
[ ]
146
291
F32+R
Batch 2 average temperature standard
4
2
°C
147
293
F32+R
Batch 2 average density process
4
2
kg/m3
148
295
F32+R
Batch 2 average flow proces
4
1
m3/h
149
297
F32+R
Batch 2 average density proving external flowmeter
4
8
kg/m3
150
299
F32+R
Batch 2 average flow proving external flowmeter
4
8
m3/h
151
301
F32+R
Batch 2 average installed Kfactor proving (external flowmeter)
4
8
puls/liter
152
303
F32+R
Batch 2 found new Kfactor proving (external flowmeter)
4
8
puls/liter
153
305
F32+R
Batch 2 difference installed vs new found Kfactor (external
flowmeter)
4
8
%
154
307
F32+R
Batch 2 alarm: General flow 1-4 channels down
4
1
s
155
309
F32+R
Batch 2 alarm: General flow all channels down
4
1
s
156
311
F32+R
Batch 2 alarm: calculation API group mismatch
4
2
s
157
313
F32+R
Batch 2 alarm: system runtime alarm occured
4
1
s
158
315
F32+R
Batch 2 alarm: real time profile out of range when used
4
1
s
159
317
F32+R
Batch 2 alarm: measurement out of range temperature body
4
1
s
160
319
F32+R
Batch 2 alarm: measurement out of range temperature process
4
2
s
161
321
F32+R
Batch 2 alarm: measurement out of range temperature proving
4
8
s
162
323
F32+R
Batch 2 alarm: measurement out of range temperature densitometer
4
2
s
163
325
F32+R
Batch 2 alarm: measurement out of range pressure process
4
1
2
s
164
327
F32+R
Batch 2 alarm: measurement out of range pressure proving (extern
4
8
s
165
329
F32+R
Batch 2 alarm: measurement out of range pressure densitometer
4
2
s
166
331
F32+R
Batch 2 alarm: measurement out of range density densitometer
4
2
s
167
333
F32+R
Batch 2 alarm: measurement out of range density standard
4
2
s
168
335
F32+R
Batch 2 alarm: measurement out of range viscosity external
4
1
s
169
337
F32+R
Batch 2 alarm: OVERRIDE applied temperature body
4
1
s
170
339
F32+R
Batch 2 alarm: OVERRIDE applied temperature process
4
2
s
171
341
F32+R
Batch 2 alarm: OVERRIDE applied temperature proving (ext
flowmeter)
4
8
s
172
343
F32+R
Batch 2 alarm: OVERRIDE applied temperature densitometer
4
2
s
173
345
F32+R
Batch 2 alarm: OVERRIDE applied pressure process
4
1
2
s
174
347
F32+R
Batch 2 alarm: OVERRIDE applied pressure proving (ext flowmeter)
4
8
s
175
349
F32+R
Batch 2 alarm: OVERRIDE applied pressure densitometer
4
2
s
176
351
F32+R
Batch 2 alarm: OVERRIDE applied density densitometer
4
2
s
177
353
F32+R
Batch 2 alarm: OVERRIDE applied density standard
4
2
s
178
355
F32+R
Batch 2 alarm: OVERRIDE applied viscosity external
4
1
s
179
357
F32+R
Service Value: temperature body
9
1
°C
180
359
F32+R
Service Value: temperature process
9
2
°C
181
361
F32+R
Service Value: temperature proving (external flowmeter)
9
8
°C
182
363
F32+R
Service Value: temperature densitometer
9
2
°C
183
365
F32+R
Service Value: presure process
9
1
2
bar
184
367
F32+R
Service Value: pressure Proving (external flowmeter)
9
8
bar
185
369
F32+R
Service Value: pressure densitometer
9
2
bar
186
371
F32+R
Service Value: density densitometer
9
2
kg/m3
187
373
F32+R
Service Value: density standard
9
2
kg/m3
188
375
F32+R
Service Value: viscosity external
9
1
cSt or 10-6 m2/s
189
377
F32+R
Channel 1 indicative flow velocity in primary section
5
1
m/s
190
379
F32+R
Channel 2 indicative flow velocity in primary section
5
1
m/s
191
381
F32+R
Channel 3 indicative flow velocity in primary section
5
1
m/s
192
383
F32+R
Channel 4 indicative flow velocity in primary section
5
1
m/s