beautypg.com

KROHNE ALTOSONIC V Modbus EN User Manual

Page 43

background image

ALTOSONIC V

ModBus Manual 0300 rev07 E

7.30855.35.00

Page 43 of 64

140

279

F32+R

Batch 2 average Ctl (15°C to standard)

4

2

[ ]

141

281

F32+R

Batch 2 average Cpl (0 bar to standard. always 1)

4

2

[ ]

142

283

F32+R

Batch 2 average Ctl (15°C to densitometer)

4

2

[ ]

143

285

F32+R

Batch 2 average Cpl (0 bar to densitometer)

4

2

[ ]

144

287

F32+R

Batch 2 average Ctl (15°C to proving external flowmeter)

4

8

2

[ ]

145

289

F32+R

Batch 2 average Cpl (0 bar to proving external flowmeter)

4

8

2

[ ]

146

291

F32+R

Batch 2 average temperature standard

4

2

°C

147

293

F32+R

Batch 2 average density process

4

2

kg/m3

148

295

F32+R

Batch 2 average flow proces

4

1

m3/h

149

297

F32+R

Batch 2 average density proving external flowmeter

4

8

kg/m3

150

299

F32+R

Batch 2 average flow proving external flowmeter

4

8

m3/h

151

301

F32+R

Batch 2 average installed Kfactor proving (external flowmeter)

4

8

puls/liter

152

303

F32+R

Batch 2 found new Kfactor proving (external flowmeter)

4

8

puls/liter

153

305

F32+R

Batch 2 difference installed vs new found Kfactor (external
flowmeter)

4

8

%

154

307

F32+R

Batch 2 alarm: General flow 1-4 channels down

4

1

s

155

309

F32+R

Batch 2 alarm: General flow all channels down

4

1

s

156

311

F32+R

Batch 2 alarm: calculation API group mismatch

4

2

s

157

313

F32+R

Batch 2 alarm: system runtime alarm occured

4

1

s

158

315

F32+R

Batch 2 alarm: real time profile out of range when used

4

1

s

159

317

F32+R

Batch 2 alarm: measurement out of range temperature body

4

1

s

160

319

F32+R

Batch 2 alarm: measurement out of range temperature process

4

2

s

161

321

F32+R

Batch 2 alarm: measurement out of range temperature proving

4

8

s

162

323

F32+R

Batch 2 alarm: measurement out of range temperature densitometer

4

2

s

163

325

F32+R

Batch 2 alarm: measurement out of range pressure process

4

1

2

s

164

327

F32+R

Batch 2 alarm: measurement out of range pressure proving (extern

4

8

s

165

329

F32+R

Batch 2 alarm: measurement out of range pressure densitometer

4

2

s

166

331

F32+R

Batch 2 alarm: measurement out of range density densitometer

4

2

s

167

333

F32+R

Batch 2 alarm: measurement out of range density standard

4

2

s

168

335

F32+R

Batch 2 alarm: measurement out of range viscosity external

4

1

s

169

337

F32+R

Batch 2 alarm: OVERRIDE applied temperature body

4

1

s

170

339

F32+R

Batch 2 alarm: OVERRIDE applied temperature process

4

2

s

171

341

F32+R

Batch 2 alarm: OVERRIDE applied temperature proving (ext
flowmeter)

4

8

s

172

343

F32+R

Batch 2 alarm: OVERRIDE applied temperature densitometer

4

2

s

173

345

F32+R

Batch 2 alarm: OVERRIDE applied pressure process

4

1

2

s

174

347

F32+R

Batch 2 alarm: OVERRIDE applied pressure proving (ext flowmeter)

4

8

s

175

349

F32+R

Batch 2 alarm: OVERRIDE applied pressure densitometer

4

2

s

176

351

F32+R

Batch 2 alarm: OVERRIDE applied density densitometer

4

2

s

177

353

F32+R

Batch 2 alarm: OVERRIDE applied density standard

4

2

s

178

355

F32+R

Batch 2 alarm: OVERRIDE applied viscosity external

4

1

s

179

357

F32+R

Service Value: temperature body

9

1

°C

180

359

F32+R

Service Value: temperature process

9

2

°C

181

361

F32+R

Service Value: temperature proving (external flowmeter)

9

8

°C

182

363

F32+R

Service Value: temperature densitometer

9

2

°C

183

365

F32+R

Service Value: presure process

9

1

2

bar

184

367

F32+R

Service Value: pressure Proving (external flowmeter)

9

8

bar

185

369

F32+R

Service Value: pressure densitometer

9

2

bar

186

371

F32+R

Service Value: density densitometer

9

2

kg/m3

187

373

F32+R

Service Value: density standard

9

2

kg/m3

188

375

F32+R

Service Value: viscosity external

9

1

cSt or 10-6 m2/s

189

377

F32+R

Channel 1 indicative flow velocity in primary section

5

1

m/s

190

379

F32+R

Channel 2 indicative flow velocity in primary section

5

1

m/s

191

381

F32+R

Channel 3 indicative flow velocity in primary section

5

1

m/s

192

383

F32+R

Channel 4 indicative flow velocity in primary section

5

1

m/s