ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 35 of 64
8.3
Field 2 (Read only Integer Field)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and
with functions 6 and 16 in Modbus master mode.
By default the start addresses are mapped to address 3000 (default value)
s
ta
rt
a
d
d
re
s
s
M
o
d
ic
o
n
C
o
m
p
N
o
tM
o
d
ic
o
n
C
o
m
p
T
y
p
e
+
A
c
c
e
s
s
D
e
s
c
ri
p
ti
o
n
Le
ve
l
Le
ve
l
Le
ve
l
R
e
m
a
rk
1
I16+R
Flow process
1
scaled –32768…32767 ó -125%… +125%
2
I16+R
Sound velocity average
1
scaled –32768…32767 ó -3276.8…3276.7
m/s
3
I16+R
Temperature process
2
scaled –32768…32767 ó -327.68…327.67
°C
4
I16+R
Pressure process
1
2
scaled –32768…32767 ó -327.68…327.67
Bar
5
I16+R
Density process
2
scaled 0...32767 ó 0…1683.35 kg/m3
6
I16+R
Temperature body
1
scaled –32768…32767 ó -327.68...327.67
°C
7
I16+R
Flow standard
2
scaled –32768…32767 ó -125% …+125%
8
I16+R
Flow mass
2
scaled –32768…32767 ó -125% …+125%
9
I16+R
Flow of channel 1
5
1
scaled –32768…32767 ó -125% …+125%
10
I16+R
Flow of channel 2
5
1
scaled –32768…32767 ó -125% …+125%
11
I16+R
Flow of channel 3
5
1
scaled –32768…32767 ó -125% …+125%
12
I16+R
Flow of channel 4
5
1
scaled –32768…32767 ó -125% …+125%
13
I16+R
Flow of channel 5
5
1
scaled –32768…32767 ó -125% …+125%
14
I16+R
Sound velocity of channel 1
5
1
scaled 0…32767 ó 0…3276.7 m/s
15
I16+R
Sound velocity of channel 2
5
1
scaled 0…32767 ó 0…3276.7 m/s
16
I16+R
Sound velocity of channel 3
5
1
scaled 0…32767 ó 0…3276.7 m/s
17
I16+R
Sound velocity of channel 4
5
1
scaled 0…32767 ó 0…3276.7 m/s
18
I16+R
Sound velocity of channel 5
5
1
scaled 0…32767 ó 0…3276.7 m/s
19
I16+R
Density meter choice
2
0=AD /Modbus input
1=Solartron1
2=Solartron2
3=Sarasota 1
4=Sarasota2
5=Freq-span
20
I16+R
UFP batch1 ticket number
4
0…32767
21
I16+R
UFP batch1 status
4
0=non
1=setup
2=running
3=end-batch
5=end-printing
6=end-printfail
7=confirm
10=reset
22
I16+R
UFP batch1 printer status
4
0=Ready to print1=Fail in printing
2=Busy (During print task)
2=Check for printer connection (when no
print task)
3=No printer connection
23
I16+R
UFP batch1 print task
4
0 =No print task
1…2 =Attempt to print first character of
header
3 =Time out value countdown for
actual printing
4…98 =Printing headers
24
I16+R
Reserved
25
I16+R
System set-up warning/error number
5
1
[ ]
26
I16+R
System runtime warning/error number
5
1
[ ]