KROHNE ALTOSONIC V Modbus EN User Manual
Page 30
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 30 of 64
24
B+R
Totaliser standard: totaliser reset occurred
2
5
25
B+R
Totaliser process: forward totaliser rollover occurred
1
5
26
B+R
Totaliser process: reverse totaliser rollover occurred
1
5
27
B+R
Totaliser standard: forward totaliser rollover occurred
2
5
28
B+R
Totaliser standard: reverse totaliser rollover occurred
2
5
29
B+R
Totaliser mass: sum totalizer rollover occurred
2
5
30
B+R
Totaliser mass: totalizer reset occurred
2
5
31
B+R
Totaliser mass: forward totalizer rollover occurred
2
5
32
B+R
Totaliser mass: reverse totalizer rollover occurred
2
5
33
B+R
Over range data path 1
1
5
34
B+R
Over range data path 2
1
5
35
B+R
Over range data path 3
1
5
36
B+R
Over range data path 4
1
5
37
B+R
Over range data path 5
1
5
38
B+R
Path failure path 1
1
5
39
B+R
Path failure path 2
1
5
40
B+R
Path failure path 3
1
5
41
B+R
Path failure path 4
1
5
42
B+R
Path failure path 5
1
5
43
B+R
Deviation in sound velocity path 1
1
5
44
B+R
Deviation in sound velocity path 2
1
5
45
B+R
Deviation in sound velocity path 3
1
5
46
B+R
Deviation in sound velocity path 4
1
5
47
B+R
Deviation in sound velocity path 5
1
5
48
B+R
Communication failure path 1
1
5
49
B+R
Communication failure path 2
1
5
50
B+R
Communication failure path 3
1
5
51
B+R
Communication failure path 4
1
5
52
B+R
Communication failure path 5
1
5
53
B+R
Real profile sampling on hold. By channel fails or flow dev
1
5
54
B+R
Alarm on reading: external Viscosity
1
5
Default:not used
55
B+R
Alarm on reading: temperature densitometer
2
5
56
B+R
Alarm on reading: pressure densitometer
2
5
57
B+R
Alarm on reading: temperature proving (external flowmeter)
8
5
58
B+R
Alarm on reading: pressure proving (external flowmeter)
8
5
59
B+R
Densitometer switch alarm
2
5
60
B+R
Real profile out of range during correction of channel(s)
1
5
61
B+R
Alarm on reading: standard density input
2
5
62
B+R
Alarm on service value: temperature body
1
5
63
B+R
Alarm on service value: temperature process
1
2
5
64
B+R
Alarm on service value: temperature proving (ext flowm)
9
8
5
65
B+R
Alarm on service value: temperature densitometer
9
5
66
B+R
Alarm on service value: pressure process
9
5
67
B+R
Alarm on service value: pressure proving (ext .flowm.)
9
8
5
68
B+R
Alarm on service value: pressure densitometer
9
5
69
B+R
Alarm on service value: densitometer density
9
5
70
B+R
Alarm on service value: standard density
9
5
71
B+R
Alarm on service value: viscosity external
9
5
72
B+R
OVERRIDE enable possible for temperature body
1
7
73
B+R
OVERRIDE enable possible for temperature process
2
7
74
B+R
OVERRIDE enable possible for temperature proving (ext flowm)
8
7
75
B+R
OVERRIDE enable possible for temperature densitometer
2
7
76
B+R
OVERRIDE enable possible for pressure process
1
2
7