KROHNE ALTOSONIC V Modbus EN User Manual
Page 38
ALTOSONIC V
ModBus Manual 0300 rev07 E
7.30855.35.00
Page 38 of 64
8.4
Field 3 (Read only Long Integer Field)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and
with functions 6 and 16 in Modbus master mode.
By default the start addresses are mapped to address 5000 (default value)
s
ta
rt
a
d
d
re
s
s
N
o
tM
o
d
ic
o
n
C
o
m
p
s
ta
rt
a
d
d
re
s
s
M
o
d
ic
o
n
C
o
m
p
T
y
p
e
+
A
c
c
e
s
s
D
e
s
c
ri
p
ti
o
n
Le
ve
l
Le
ve
l
Le
ve
l
R
e
m
a
rk
1
1
I32+R
Resetable totaliser process sum
1
liter
2
3
I32+R
Flow process
1
scaled -32768 ... +32767 ó
-125% …+125%
3
5
I32+R
Sound velocity average
5
scaled 0…32767 ó
0…3276.7 m/s
4
7
I32+R
resetable totaliser standard sum
2
liter
5
9
I32+R
Flow standard
2
scaled -32768 … +32767 ó
-125%… +125%
6
11
I32+R
Resetable totalizer mass sum
2
kg
7
13
I32+R
Flow: mass
2
scaled -32768 … +32767 ó
-125%… +125%
8
15
I32+R
UFP batch1 ticket count
4
0….2147483647
9
17
I32+R
Resetable totaliser: process forward
1
liter
10
19
I32+R
Resetable totaliser: process reverse
1
liter
11
21
I32+R
Resetable totaliser: standard forward
2
liter
12
23
I32+R
Resetable totaliser: standard reverse
2
liter
13
25
I32+R
Resetable totaliser: mass forward
2
kg
14
27
I32+R
Resetable totaliser: mass reverse
2
kg
15
29
I32+R
UFP serial number
1
[ ]
16
31
I32+R
Software version
1
[ ]
17
33
I32+R
System set-up warning/error number
1
[ ]
18
35
I32+R
System runtime warning/error number
1
[ ]
19
37
I32+R
System messages 01...32
1
[ ]
20
39
I32+R
System messages 33...64
1
[ ]
21
41
I32+R
Resetable totaliser: external flowmeter actual total
8
liter
22
43
I32+R
Resetable totaliser: external flowmeter standard total
8
liter
23
45
I32+R
Resetable totaliser: external flowmeter mass total
8
kg
24
47
I32+R
Process time (resets on totaliser reset)
5
s, used as watch dog for
host
25
49
I32+R
Non resetable totaliser: process sum
1
0.1m3
26
51
I32+R
Non resetable totaliser: process forward
1
0.1m3
27
53
I32+R
Non resetable totaliser: process reverse
1
0.1m3
28
55
I32+R
Non resetable totaliser: standard sum
2
0.1m3
29
57
I32+R
Non resetable totaliser: standard forward
2
0.1m3
30
59
I32+R
Non resetable totaliser: standard reverse
2
0.1m3
31
61
I32+R
Non resetable totaliser: mass sum
2
0.1 ton
32
63
I32+R
Non resetable totaliser: mass forward
2
0.1 ton
33
65
I32+R
Non resetable totaliser: mass reverse
2
0.1 ton
34
67
I32+R
Resetable totaliser: process sum (nett.oil)
3
liter
35
69
I32+R
Resetable totaliser: process forward (nett.oil)
3
liter
36
71
I32+R
Resetable totaliser: process reverse (nett.oil)
3
liter
37
73
I32+R
Resetable totaliser: standard sum (nett.oil)
3
liter
38
75
I32+R
Resetable totaliser: standard forward (nett.oil)
3
liter
39
77
I32+R
Resetable totaliser: standard reverse (nett.oil)
3
liter
40
79
I32+R
Resetable totaliser: mass sum (nett.oil)
3
kg