beautypg.com

KROHNE ALTOSONIC V Modbus EN User Manual

Page 38

background image

ALTOSONIC V

ModBus Manual 0300 rev07 E

7.30855.35.00

Page 38 of 64

8.4

Field 3 (Read only Long Integer Field)

This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and

with functions 6 and 16 in Modbus master mode.

By default the start addresses are mapped to address 5000 (default value)

s

ta

rt

a

d

d

re

s

s

N

o

tM

o

d

ic

o

n

C

o

m

p

s

ta

rt

a

d

d

re

s

s

M

o

d

ic

o

n

C

o

m

p

T

y

p

e

+

A

c

c

e

s

s

D

e

s

c

ri

p

ti

o

n

Le

ve

l

Le

ve

l

Le

ve

l

R

e

m

a

rk

1

1

I32+R

Resetable totaliser process sum

1

liter

2

3

I32+R

Flow process

1

scaled -32768 ... +32767 ó
-125% …+125%

3

5

I32+R

Sound velocity average

5

scaled 0…32767 ó
0…3276.7 m/s

4

7

I32+R

resetable totaliser standard sum

2

liter

5

9

I32+R

Flow standard

2

scaled -32768 … +32767 ó
-125%… +125%

6

11

I32+R

Resetable totalizer mass sum

2

kg

7

13

I32+R

Flow: mass

2

scaled -32768 … +32767 ó
-125%… +125%

8

15

I32+R

UFP batch1 ticket count

4

0….2147483647

9

17

I32+R

Resetable totaliser: process forward

1

liter

10

19

I32+R

Resetable totaliser: process reverse

1

liter

11

21

I32+R

Resetable totaliser: standard forward

2

liter

12

23

I32+R

Resetable totaliser: standard reverse

2

liter

13

25

I32+R

Resetable totaliser: mass forward

2

kg

14

27

I32+R

Resetable totaliser: mass reverse

2

kg

15

29

I32+R

UFP serial number

1

[ ]

16

31

I32+R

Software version

1

[ ]

17

33

I32+R

System set-up warning/error number

1

[ ]

18

35

I32+R

System runtime warning/error number

1

[ ]

19

37

I32+R

System messages 01...32

1

[ ]

20

39

I32+R

System messages 33...64

1

[ ]

21

41

I32+R

Resetable totaliser: external flowmeter actual total

8

liter

22

43

I32+R

Resetable totaliser: external flowmeter standard total

8

liter

23

45

I32+R

Resetable totaliser: external flowmeter mass total

8

kg

24

47

I32+R

Process time (resets on totaliser reset)

5

s, used as watch dog for
host

25

49

I32+R

Non resetable totaliser: process sum

1

0.1m3

26

51

I32+R

Non resetable totaliser: process forward

1

0.1m3

27

53

I32+R

Non resetable totaliser: process reverse

1

0.1m3

28

55

I32+R

Non resetable totaliser: standard sum

2

0.1m3

29

57

I32+R

Non resetable totaliser: standard forward

2

0.1m3

30

59

I32+R

Non resetable totaliser: standard reverse

2

0.1m3

31

61

I32+R

Non resetable totaliser: mass sum

2

0.1 ton

32

63

I32+R

Non resetable totaliser: mass forward

2

0.1 ton

33

65

I32+R

Non resetable totaliser: mass reverse

2

0.1 ton

34

67

I32+R

Resetable totaliser: process sum (nett.oil)

3

liter

35

69

I32+R

Resetable totaliser: process forward (nett.oil)

3

liter

36

71

I32+R

Resetable totaliser: process reverse (nett.oil)

3

liter

37

73

I32+R

Resetable totaliser: standard sum (nett.oil)

3

liter

38

75

I32+R

Resetable totaliser: standard forward (nett.oil)

3

liter

39

77

I32+R

Resetable totaliser: standard reverse (nett.oil)

3

liter

40

79

I32+R

Resetable totaliser: mass sum (nett.oil)

3

kg