Profibus settings – KROHNE MFC 400 Profibus User Manual
Page 50
5
PROFIBUS SETTINGS
50
MFC 400
www.krohne.com
06/2013 - 4002835301 - AD MFC 400 PROFIBUS R01 en
C6.1 Device Info
C6 Device
In this menu all functions are grouped that have no effect on the measurement or any output directly.
C6.1.1
Tag
Tag descriptor of the physical block of the PROFIBUS module will be
displayed. The Tag descriptor provides an application specific reference to
the blocks. It will be assigned by the user of the device. The Tag descriptor is
an octet string (a visible string will be preferred) consisting of 32 byte. The
first 21 characters will be displayed only!
C6.3
1st Meas. Page
C6.3.1
Function
Specify number of measured value lines (font size)
One Line / Two Lines / Three Lines
C6.3.2
Measurement 1.line
Select the measurement of the 1st line:
Select:
Volume Flow / Mass Flow / Temperature / Density / Flow Velocity /
Sensor Average / Sensor Deviation / Drive Level / Tube Frequency / Strain 1 /
Strain 2 / 2 Phase Signal
If option "Concentration measurement" is released below mentioned
additional measurement values are selectable:
Concentration 1 / Concentration 2 / Conc. mass flow 1 /
Conc. volume flow 1 / Conc. mass flow 2 / Conc. volume flow 2
C6.3.8
Measurement 2.line
Specify measurement of 2nd line (only available if this 2.line is activated)
Select:
Bargraph / Volume Flow / Mass Flow / Temperature / Density /
Flow Velocity / Sensor Average / Sensor Deviation / Drive Level /
Tube Frequency / Strain 1 / Strain 2 / 2 Phase Signal / FB4 Total. 1 /
FB5 Total. 2 / FB6 Total. 3 / Operating Hours
If option "Concentration measurement" is released below mentioned
additional measurement values are selectable:
Concentration 1 / Concentration 2 / Conc. mass flow 1 /
Conc. volume flow 1 / Conc. mass flow 2 / Conc. volume flow 2
C6.3.10
Measurement 3.line
Specify measurement of 3rd line (only available if this 3.line is activated)
Select:
Volume Flow / Mass Flow / Temperature / Density / Flow Velocity /
Sensor Average / Sensor Deviation / Drive Level / Tube Frequency / Strain 1 /
Strain 2 / 2 Phase Signal / FB4 Total. 1 / FB5 Total. 2 / FB6 Total. 3 /
Operating Hours
If option "Concentration measurement" is released below mentioned
additional measurement values are selectable:
Concentration 1 / Concentration 2 / Conc. mass flow 1 /
Conc. volume flow 1 / Conc. mass flow 2 / Conc. volume flow 2
C6.4
2. Meas. page
Setting of the measurement for the second measuring page.
For PROFIBUS devices this page shows only the PROFIBUS values
FB1…FB8.
C6.4.1
C6.4.3
C6.4.5
Measurement 1.line
Measurement 2.line
Measurement 3.line
Select the measurement of the 1st, 2nd and 3rd line:
FB1 Analog inp. 1 / FB2 Analog inp. 2 / FB3 Analog inp. 3 / FB4 Totaliser 1 /
FB5 Totaliser 2 / FB6 Totaliser 3 / FB7 Analog inp. 4 / FB8 Analog inp. 5 /
FB9 Analog inp. 6 / FB10 Analog inp. 7 / FB11 Analog inp. 8
C6.4.2
C6.4.4
C6.4.6
Format 1.line
Format 2.line
Format 3.line
Fixed number of digits after the decimal point or automatic, where the
number of digits is automatically adjusted to the available space.
C6.8
Physical Block
This menu is only available, if a PROFIBUS interface is present.