Commissioning / operation, 3 variable "event groups – KROHNE MFC 400 Profibus User Manual
Page 42
4
COMMISSIONING / OPERATION
42
MFC 400
www.krohne.com
06/2013 - 4002835301 - AD MFC 400 PROFIBUS R01 en
How to read the mapping table above:
• If e.g. the diagnosis event bit of "Event group" ("I-") Electr: Info. Operation
Electr: Info. Operation
Electr: Info. Operation
Electr: Info. Operation (81) has been set
the diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) will be set additionally.
• If e.g. the diagnosis event bit of "Event group" "C
C
C
C – Sensor
Sensor
Sensor
Sensor" (59) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Function check"
(42) will be set additionally.
• If e.g. the diagnosis event bit of "Event group" "M
M
M
M – Sensor
Sensor
Sensor
Sensor" (67) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Maintenance
Maintenance
Maintenance
Maintenance
required
required
required
required" (37) will be set additionally.
• If e.g. the diagnosis event bit of "Event group" "S
S
S
S – Sensor
Sensor
Sensor
Sensor" (71) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Measurement
Measurement
Measurement
Measurement
failure
failure
failure
failure" (29) will be set additionally.
• If e.g. the diagnosis event bit of "Event group" "F
F
F
F – Sensor
Sensor
Sensor
Sensor" (63) has been set both the
diagnosis event bit "Extension available
Extension available
Extension available
Extension available" (55) and the diagnosis event bit "Hardware failure
Hardware failure
Hardware failure
Hardware failure
electronics
electronics
electronics
electronics" (24) will be set additionally.
4.3.3 Variable "Event groups"
As already mentioned in the MFC 400 Handbook there are 8 "Event groups" available with a
variable classification ("F", "S", "M", "C" or "I"):
• ("I-") Electr: Power Failure
• ("I-") Proc: System Control
• ("S-") Config_ Totalizer
• ("S-") Proc: Signal Low
• ("S-") Proc: 2 Phase Flow
• ("F-") Proc: Signal Search
• ("S-") Electr: IO Connection
• ("F-") Proc: Current Input
If using the DTM
DTM
DTM
DTM you are able to choose one of the following settings:
Enter menu: → "Parameters → Input → Diagnostics":
CAUTION!
It is strongly recommended
strongly recommended
strongly recommended
strongly recommended to use the default
default
default
default classification. If the default classification of a
variable "Event Group" should be changed please note: