Commissioning / operation, 3 variable "event groups – KROHNE MFC 400 Profibus User Manual

Page 42

background image

4

COMMISSIONING / OPERATION

42

MFC 400

www.krohne.com

06/2013 - 4002835301 - AD MFC 400 PROFIBUS R01 en

How to read the mapping table above:

• If e.g. the diagnosis event bit of "Event group" ("I-") Electr: Info. Operation

Electr: Info. Operation

Electr: Info. Operation

Electr: Info. Operation (81) has been set

the diagnosis event bit "Extension available

Extension available

Extension available

Extension available" (55) will be set additionally.

• If e.g. the diagnosis event bit of "Event group" "C

C

C

C Sensor

Sensor

Sensor

Sensor" (59) has been set both the

diagnosis event bit "Extension available

Extension available

Extension available

Extension available" (55) and the diagnosis event bit "Function check"

(42) will be set additionally.

• If e.g. the diagnosis event bit of "Event group" "M

M

M

M Sensor

Sensor

Sensor

Sensor" (67) has been set both the

diagnosis event bit "Extension available

Extension available

Extension available

Extension available" (55) and the diagnosis event bit "Maintenance

Maintenance

Maintenance

Maintenance

required

required

required

required" (37) will be set additionally.

• If e.g. the diagnosis event bit of "Event group" "S

S

S

S Sensor

Sensor

Sensor

Sensor" (71) has been set both the

diagnosis event bit "Extension available

Extension available

Extension available

Extension available" (55) and the diagnosis event bit "Measurement

Measurement

Measurement

Measurement

failure

failure

failure

failure" (29) will be set additionally.

• If e.g. the diagnosis event bit of "Event group" "F

F

F

F Sensor

Sensor

Sensor

Sensor" (63) has been set both the

diagnosis event bit "Extension available

Extension available

Extension available

Extension available" (55) and the diagnosis event bit "Hardware failure

Hardware failure

Hardware failure

Hardware failure

electronics

electronics

electronics

electronics" (24) will be set additionally.

4.3.3 Variable "Event groups"

As already mentioned in the MFC 400 Handbook there are 8 "Event groups" available with a
variable classification ("F", "S", "M", "C" or "I"):

• ("I-") Electr: Power Failure
• ("I-") Proc: System Control
• ("S-") Config_ Totalizer
• ("S-") Proc: Signal Low
• ("S-") Proc: 2 Phase Flow
• ("F-") Proc: Signal Search
• ("S-") Electr: IO Connection
• ("F-") Proc: Current Input

If using the DTM

DTM

DTM

DTM you are able to choose one of the following settings:

Enter menu: → "Parameters → Input → Diagnostics":

CAUTION!
It is strongly recommended

strongly recommended

strongly recommended

strongly recommended to use the default

default

default

default classification. If the default classification of a

variable "Event Group" should be changed please note: