Installation – KROHNE OPTISYS SLM 2100 EN User Manual
Page 20

3
INSTALLATION
20
OPTISYS SLM 2100
www.krohne.com
03/2014 - 4002737302 - MA OPTISYS SLM 2100 R02 en
3.5.1 Installation of the water hose
A 3/4" connector wit metric thread provides the mounting point for the water hose adapter.
When installing the water hose adapter on the connector, carefully fix the nut of the fitting. The
electric valve inside the cleaning system housing maybe twisted, which may cause water
leakage. If it is not possible to tighten the nut of the hose fitting adequately, remove the lower
cover of the cleaning unit and lock the nut mounted in the electric value.
When installing the device, make sure the water hose is adequately fixed as outlined. Mount the
water hose in such a way that the weight of it is not carried by the hose adaptor. When fixing the
hose also take into account that it must be avoided that it moves when the system is switched
on/off.
WARNING!
The maximum allowed water pressure should not exceed 6 bar / 87 psi.
INFORMATION!
An external separation switch of the water supply have to be located close to the device and
easily accessible.
Figure 3-7: Fixing points water hose
1 Water hose
2 Fixing points
.book Page 20 Wednesday, April 30, 2014 1:39 PM