B.16 [SOURce:]OUTPut:PROTection:SHORt[:STATe] COMMAND
OUTP:PROT:SHOR
Syntax:
Short Form: [SOUR:]INP:PROT:SHOR[:STAT]
Long Form: [SOURce:]INPut:PROTection:SHORt[:STATe]
Description: Applies maximum drive to FETs, effectively shorting the output.
B.17 [SOURce:]MEASure:ALL? QUERY
MEAS:ALL?
Syntax:
Short Form: [SOUR:]MEAS:ALL? Long
Form:
[SOURce:]MEASure:ALL?
Returns: Measured values in the form 0.000 KW, 0.000 Amps, 0.000 Volts.
Description: Measures output power (Kilowatts), current (Amps), and voltage (Volts). Unit of measurement included
in the reply.
B.18 [SOURce:]MEASure:ALL2? QUERY
MEAS:ALL2?
Syntax:
Short Form: [SOUR:]MEAS:ALL2? Long
Form:
[SOURce:]MEASure:ALL2?
Returns: Measured values in the form 0.000 0.000 0.000 (Kilowatts Amps Volts).
Description: Measures output power (Kilowatts), current (Amps), and voltage (Volts). Unit of measurement is omit-
ted from the reply.
B.19 [SOURce:]MEASure[:SCALar]:CURRent[:DC]? QUERY
MEAS:CURR?
Syntax:
Short Form: [SOUR:]MEAS[:SCAL]:CURR[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:CURRent[:DC]?
Returns: Measured values.
Description: Measures current. Measured value returned as XXX Amps, where XXX is decimal data representing
measured current.
B.20 [SOURce:]MEASure[:SCALar]:POWer[:DC]? QUERY
MEAS:POW?
Syntax:
Short Form: [SOUR:]MEAS[:SCAL]:POW[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:POWer[:DC]?
Returns: Measured values in the form 0.000 Kilowatts
Description: Measures power. Measured value returned as XXX Kilowatts, where XXX represents measured
power.
B.21 [SOURce:]MEASure[:SCALar]:VOLTage[:DC]? QUERY
MEAS:VOLT?
Syntax:
Short Form: [SOUR:]MEAS[:SCAL]:VOLT[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:VOLTage[:DC]?
Returns: Measured values in the form XXX Volts
Description: Measures voltage. Measured value returned as XXX Volts, where XXX is decimal data representing
measured voltage.
B.22 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude] COMMAND
COND
Syntax:
Short Form:[SOUR:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]
Where
Description: Establishes conductance setpoint. Conductance setpoint affects the load only when the load is in
Conductance mode of operation. Conductance setpoint is stored in non-volatile memory; value is
restored upon power-up.
B.23 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]? QUERY
COND?
Syntax:
Short Form:[SOUR:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]?
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]?
Returns
Description: Indicates conductance setpoint.