GW Instek GDS-1000 Series Programming Manual User Manual
Page 25
COMMAND
DETAILS
49
Description
Starts waiting for a trigger condition.
Same as: Run key
Syntax :run
78B
:SINGle
Set
Description
Selects the single trigger mode and starts waiting
for a trigger condition.
Same as: (Trigger) Single key
Syntax
:single
:singl
79B
:STOP
Set
Description
Stops waiting for a trigger condition.
Same as: Stop key
Syntax :stop
80B
*TRG
Set
Description
Manually triggers the GDS-1000 and displays the
input signals.
Same as: (Trigger) Force key
Syntax *trg
81B
:TRIGger:COUPle
Set
Query
Description
Selects or returns the trigger coupling mode.
Same as: Trigger menu key → F4 → F2
Syntax
< Long >
< Short >
GDS-1000 Programming Manual
50
:trigger:couple
:trigger:couple?
:trig:coup
:trig:coup?
Parameter
Coupling mode
1
AC
2
DC
Note
Before using this command, select the edge or
pulse trigger. See the example below.
Example :trigger:type:
0
:trigger:couple 1
Selects the edge trigger
and AC coupling mode
82B
:TRIGger:FREQuency
Query
Description
Returns the trigger frequency readout.
Syntax
< Long >
< Short >
:trigger:frequency?
:trig:freq?
83B
:TRIGger:LEVel
Set
Query
Description
Selects or returns the trigger level.
Same as: Trigger level knob
Syntax
< Long >
< Short >
:trigger:level
:trigger:level?
:trig:lev
:trig:lev?
Parameter
Trigger level in voltage
Example :trigger:level
0
Sets the trigger level at
±
0
84B
:TRIGger:MODe
Set
Query