GW Instek GDS-1000 Series Programming Manual User Manual
Page 19
COMMAND
DETAILS
37
Example :measure:source
1
:measure:vamplitude?
Selects Channel 1, and
then measures the rise
Voltage amplitude.
55B
:MEASure:VAVerage
Query
Description
Returns the average voltage.
Same as: Measure key → F1~F5 → F3 (Vavg)
Syntax
< Long >
< Short >
:measure:vaverage?
:meas:vavg?
Returns
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source
1
:measure:vaverage?
Selects Channel 1, and
then measures the
average Voltage.
56B
:MEASure:VHI
Query
Description
Returns the global high voltage.
Same as: Measure key → F1~F5 → F3 (Vhi)
Syntax
< Long >
< Short >
:measure:vhi? :meas:vhi?
Returns
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source
1
:measure:vhi?
Selects Channel 1, and
then measures the
global high Voltage.
57B
:MEASure:VLO
Query
GDS-1000 Programming Manual
38
Description
Returns the global low voltage.
Same as: Measure key → F1~F5 → F3 (Vlo)
Syntax
< Long >
< Short >
:measure:vlo? :meas:vlo?
Returns
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source
1
:measure:vlo?
Selects Channel 1, and
then measures the
global low Voltage.
58B
:MEASure:VMAX
Query
Description
Returns the maximum amplitude.
Same as: Measure key → F1~F5 → F3 (Vmax)
Syntax
< Long >
< Short >
:measure:vmax?
:meas:vmax?
Returns
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source
1
:measure:vmax?
Selects Channel 1, and
then measures the
maximum amplitude.
59B
:MEASure:VMIN
Query
Description
Returns the minimum amplitude.
Same as: Measure key → F1~F5 → F3 (Vmin)
Syntax
< Long >
< Short >
:measure:vmin?
:meas:vmin?
Returns