beautypg.com

Measure command – GW Instek GDS-1000 Series Programming Manual User Manual

Page 16

background image

COMMAND

DETAILS

31

11B

Measure command

:MEASure:FALL...........................................................

224H

31

:MEASure:FOVShoot ..................................................

225H

32

:MEASure:FPReshoot .................................................

226H

32

:MEASure:FREQuency ................................................

227H

32

:MEASure:NWIDth .....................................................

228H

33

:MEASure:PDUTy........................................................

229H

33

:MEASure:PERiod .......................................................

230H

34

:MEASure:PWIDth ......................................................

231H

34

:MEASure:RISe............................................................

232H

35

:MEASure:ROVShoot..................................................

233H

35

:MEASure:RPReshoot .................................................

234H

35

:MEASure:SOURce .....................................................

235H

36

:MEASure:VAMPlitude ...............................................

236H

36

:MEASure:VAVerage ...................................................

237H

37

:MEASure:VHI.............................................................

238H

37

:MEASure:VLO............................................................

239H

37

:MEASure:VMAX.........................................................

240H

38

:MEASure:VMIN .........................................................

241H

38

:MEASure:VPP ............................................................

242H

39

:MEASure:VRMS.........................................................

243H

39

42B

:MEASure:FALL

Query

Description

Returns the falltime measurement result.
Same as: Measure key → F1~F5 → F3 (Fall Time)

Syntax

< Long >

< Short >

:measure:fall? :meas:fall?

Returns

Note

Before using this command, select the
measurement channel. See the example below.

GDS-1000 Programming Manual

32

Example :measure:source

1

:measure:fall?

Selects Channel 1, and
then measures the fall
time.

43B

:MEASure:FOVShoot

Query

Description

Returns the fall overshoot amplitude.
Same as: Measure key → F1~F5 → F3 (FOVShoot)

Syntax

< Long >

< Short >

:measure:fovshoot?

:meas:fovs?

Returns

with % sign

Note

Before using this command, select the
measurement channel. See the example below.

Example :measure:source

1

:measure:fall?

Selects Channel 1, and
then measures the fall
overshoot.

44B

:MEASure:FPReshoot

Query

Description

Returns fall preshoot amplitude.
Same as: Measure key → F1~F5 → F3 (FPREShoot)

Syntax

< Long >

< Short >

:measure:fovshoot?

:meas:fovs?

Returns

with % sign

Note

Before using this command, select the
measurement channel. See the example below.

Example :measure:source

1

:measure:fall?

Selects Channel 1, and
then measures the fall
preshoot.

45B

:MEASure:FREQuency

Query