Options – GW Instek GPD-4303S User Manual
Page 56
GPD-X303S Series User Manual
Voltmeter
32V full scale, 5 digits 0.4" LED display
Program
Accuracy
Voltage: ± (0.03% of reading + 10mV)
Current: ± (0.3% of reading + 10mA)
Read back
Accuracy
Voltage: ± (0.03% of reading + 10mV)
Current: ± (0.3% of reading + 10mA)
CH3 of 3303S
Voltage
Current
2.5V/3.3V/5.0V, ±5%
3A
Line
≤ 3mV
Load
≤ 5mV
Ripple & Noise ≤ 1mVrms (5Hz ~ 1MHz)
Insulation Chassis
and
Terminal
20MΩ or above (DC 500V)
Chassis and
AC cord
30MΩ or above (DC 500V)
Operation
Environment
Indoor use, Altitude: ≤ 2000m
Ambient temperature: 0 ~ 40°C
Relative humidity: ≤ 80%
Installation category: II, Pollution degree: 2
Storage
Environment
Ambient temperature: –10 ~ 70°C
Relative humidity: ≤ 70%
Power Source
AC 100V/120V/220V/230V±10%, 50/60Hz
Accessories
User manual x1
Test lead GTL-104A x 2, GTL-105A x 1
(Europe) Test lead GTL-203A x 1, GTL-204A x 2
Dimensions
210 (W) x 130 (H) x 265 (D) mm
Weight
Approx. 7kg
Options
USB cable
GTL-246
USB 2.0, A-B type
56