Command Syntax

Command format

ISET:NL

1

2 3

4

5

1: command header
2: output channel
3: separator
4: parameter
5: terminator(line feed)

Output channel

1 (CH1) or 2 (CH2)

Parameter Type

Description Example

boolean logic

0 (off), 1 (on)

integers

0, 1, 2, 3

decimal numbers 0.1, 3.14, 8.5

Terminator

Each command must end with a terminal character
(new line code, ASCII: 0x0A) and each query must
end with a carriage return, ASCII: 0x0D.

Note

Commands are not case-sensitive.

Error Messages

The following error messages might appear when the GPD-X303S
cannot accept the command.

Message contents

Descriptions

a Program

mnemonic too
long

The command length must be 15 characters
or less.

b Invalid character

Invalid characters, such as symbols, are
entered. Example: VOUT#

c Missing

parameter

The parameter is missing from the command.
Example: VSET: (should have a number)

d Data out of range

The entered value exceeds the specification.
Example: VSET:33 (should be ≤ 32V)