PSM SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 23 ⎯

Examples:

*IDN? Returns

GW.Inc,PSM-2010,A1234567,FW1.00

*OPC

Function:
The command form (*OPC) sets the operation complete bit (bit 0) in the
Standard Event Status Register (SESR) when all pending operations are
finished.

The query form (*OPC?) tells the programmable power supply to place an
ASCII 1 in the Output Queue when the power supply completes all pending
operations.

Syntax:

*OPC

*OPC?

Returns:

1

*RCL

Function:
Recall the setting data from the memory saved previously.

Syntax:

*RCL

is in the range from 0 through 99.

Examples:

*RCL 12

recalls the setting data stored in memory location 12.

PSM SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 24 ⎯

*RST

Function:
Set all control settings of power supply to their default values but does not
purge stored setting. The equivalent panel control will be set as below:

Front Panel Control

Default Setting

OUTPUT

OFF

CURRENT SET

CURRENT TRIGGER

PSM-2010:20.000A

PSM-3004:7.000A

PSM-6003:6.000A

VOLTAGE SET
VOLTAGE TRIGGER

0

DELAY

0.1 sec

OCP DELAY

0 sec

AUTO SET

OFF

RECALL (memory location) 00

OVP SET

PSM-2010:22.000V

PSM-3004:32.000V

PSM-6003:65.000V

OCP SET

PSM-2010:22.000A

PSM-3004:7.700A

PSM-6003:6.600A

STEP SET

0.001V,0.001A

RECALL RANGE

START 00

CEASE 99

CYCLE 2