beautypg.com

GW Instek PSM-Series Programming Manual User Manual

Page 11

background image

PSM SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 19 ⎯

* * 0: Voltage calibration, 1: OVP calibration, 2: Current calibration,

3: OCP calibration

z RS232 Interface Commands

SYSTem:LOCal

SYSTem:REMote

SYSTem:RWLock

z IEEE-488.2 Common Commands

*CLS

*ESE {enable value}

*ESE?

*ESR?

*IDN?

*OPC

*OPC?

*RCL {0|1|2|…..|99}

*RST

*SAV {0|1|2|…..|99}

*SRE {enable value}

*SRE?

*STB?

*TRG

*TST?

*WAI

PSM SERIES PROGRAMMABLE POWER SUPPLY

PROGRAMMER MANUAL

⎯ 20 ⎯

z Miscellaneous Commands

SYSTem:AUTO[:STATe] {OFF|ON}

SYSTem:AUTO[:STATe]?

SYSTem:AUTO:STARt {0|1|2|…..|99}

SYSTem:AUTO:STARt?

SYSTem:AUTO:CEASe {0|1|2|…..|99}

SYSTem:AUTO:CEASe?

SYSTem:AUTO:CYCLe {0*|1|2|…..|99999}

SYSTem:AUTO:CYCLe?

SYSTem:AUTO:DELay {0|1|2|…..|35999}**

SYSTem:AUTO:DELay?

* 0 : Auto, can proceed operation limitlessly ().

**Unit: 0.1second.