beautypg.com

GW Instek PEL-300 User Manual

Page 20

background image

17

(12). Setting of repeated executions:

n Press SHIFT to enable the secondary function.
o Press RCLW key.
p Key in three sets of digits with two decimals in between. The first set of the digits is specified as “the

starting batch”, the second set is specified as “the ending batch”, and the last set is specified as
“the number of executions.”

q Then press

↵ .

Example:

Œ To run batch 1 to batch 98 for 99 times

STEP 1.

SHIFT

STEP 2.

RCL W

STEP 3.

1.98.99

STEP 4.

STEP 5.

AUTO

STEP 6.

LOAD ON/OFF

Œ To retrieve data from batch 1 till batch 18

STEP 1. SHIFT

STEP 2. RCL W

STEP 3. 1.18
STEP 4.

Œ To run batch 1 to batch 98 endlessly

STEP 1.

SHIFT

STEP 2.

RCL W

STEP 3.

1.98

STEP 4.

STEP 5.

AUTO

STEP 6.

LOAD ON/OFF

Œ To retrieve data from the 10th batch

STEP 1. SHIFT

STEP 2. RCL W

STEP 3. 10
STEP 4.