BOLT CASH DISPENSER
TO FLOOR
1. Ensure the cabinet is as level
as possible given the floor
conditions. Use a bubble level
to verify this. If a bubble-level is
not available, the cabinet can be
“rocked” gently from front-to-
back and side-to-side to check
the need for leveling. Use a
screwdriver to adjust the leveling
bolts inside the unit to level the
cabinet. DO NOT extend the feet
any further than necessary to level
the cabinet.
8. Repeat steps 1-7 for each of the
remaining mounting holes.
9. Allow the adhesive to cure for the
specified time (see chart below)
prior to applying any load to the
anchors. During the winter, the
hole temperature may be different
than the room temperature! The
hole temperature should be
measured to determine the curing
time required. DO NOT disturb
or load the anchors until they are
fully cured!
Base Material Temperature*
Setting Time
68º F / 20º C and over
20 minutes
50º F / 10º C to 68º F / 20º C
30 minutes
32º F / 0º C to 50º F / 10º C
1 hour
23º F / -5º C to 32º F / 0º C
5 hours
14º F / -10º C to 23º F / -5º C
10 hours
Fig. 7. Allow seated anchor to cure.