1. This document supercedes all

other information provided by

Triton for ATM installation for

accessibility.

2. Information provided in this man-

ual is based on federal guidelines

(ADA Accessibility Guidelines

for Buildings and Facilities –

ADAAG), as amended through

January 1998. You should verify

it has not been amended. States

may also have accessibility codes.

These codes may be more restric-

tive than the federal guidelines.

Please verify this with the state

where the ATM is to be installed

prior to installation. For state

contact information, you may

call the ADA information line at

1-800-514-0301.

3. For countries other than the US,

please use the guidelines for ac-

cessibility for that country.

4. A complete copy of the ADAAG

referred to here can be found at

http://www.access-board.gov.

Included in this document is

the section of the ADAAG spe-

cifically for ATMs. For additional

information on floor surfaces and

other ADAAG requirements,

please see the complete specifica-

tion.

4.34 Automated Teller Machines.

4.34.1 General. Each automated

teller machine required to be

accessible by 4.1.3 (Accessible

Buildings:New Construction)

shall be on an accessible route

and shall comply with 4.34 (Au-

tomated Teller Machines).

4.34.2 Clear Floor Space. The

automated teller machine shall be

located so that clear floor space

complying with 4.2.4 (Clear

Floor or Ground Space for

Wheelchairs) is provided to al-

low a person using a wheelchair

to make a forward approach, a

parallel approach, or both to the

machine.

4.34.3 Reach Ranges.

(1) Forward Approach Only. If

only a forward approach is possible,

operable parts of all controls shall be

placed within the forward reach range

specified in 4.2.5 (Forward Reach).

(2) Parallel Approach Only. If only

a parallel approach is possible, oper-

able parts of controls shall be placed

as follows:

(a) Reach Depth Not More Than

10 inches (255 mm). Where the reach

depth to the operable parts of all con-

trols as measured from the vertical

plane perpendicular to the edge of the

unobstructed clear floor space at the

farthest protrusion of the automated

teller machine or surround is not

more than 10 inches (255 mm), the

maximum height above the finished

floor or grade shall be 54 inches (1370

mm).