TEMPERATURE/HUMIDITY

1. The ATM needs to be in an

environmentally-controlled

location, with no extreme fluc-

tuations in temperature or

humidity.

Generally, these parameters

must fall within the following

ranges:

Temperature

• 10-40 Deg. C

• 50-104 Deg. F

Relative Humidity

• 20% - 80%

• (Non-Condensing)

AC POWER REQUIREMENTS

2. Ensure the following AC power

requirements are met:

Isolated Ground. An equipment

grounding conductor that is insulated

from the conduit or raceway and all

other grounding points throughout

its entire length. The only points of

electrical connection will be at the

duplex outlet and service panel ends

of the line.

Dedicated source. The ATM AC

power feed will be a dedicated line, to

which no other electrical devices are

connected. The ATM power line will

be wired for a single “duplex”-style

outlet and connected directly to the

AC service panel.

DEDICATED TELEPHONE

3. Ensure the following telephone-

line

requirements are met:

Dedicated line. The telephone line

servicing the ATM will not be a

“party” line or any other shared type

connection.

Proximity to Interference Sources.

The telephone line must not be in

close proximity to “noisy” devices

that could induce interference into the

ATM communications channel.

Current (Max)

• 5.05A @ 120V

• 2.01A @ 240V

Voltage

• 90V - 136V @ 50/60 Hz

• 198V - 257V @ 50/60 Hz

Power Consumption (Idle)

• 2.0A @ 115 VAC at 60 Hz

• 1.0A @ 230 VAC at 50 Hz

Power Consumption (Max Load)

• 606 Watts @ 120V

• 482 Watts @ 240V

RF INTERFERENCE

4. Ensure there are no devices

near the terminal that may

cause RF interference, such as:

TVs

Coolers

Security Devices

Neon Signs

Devices with Compressors

When installing an ATM, some general environmental precautions