background image

12

4.2.4.2 Relationship of Maneuver-

ing Clearance to Wheelchair Spaces.

One full unobstructed side of the clear

floor or ground space for a wheelchair

shall adjoin or overlap an accessible

route or adjoin another wheelchair

clear floor space. If a clear floor space

is located in an alcove or otherwise

confined on all or part of three sides,

additional maneuvering clearances

shall be provided as shown in Fig. 4(d)

and 4(e).

4.2.4.3 Surfaces for Wheelchair

Spaces. Clear floor or ground spaces

for wheelchairs shall comply with 4.5.

4.2.5

Forward Reach. If the

clear floor space only allows forward

approach to an object, the maximum

high forward reach allowed shall be

48 inches (1220 mm) (see Fig. 5(a)).

The minimum low forward reach is 15

inches (380 mm). If the high forward

reach is over an obstruction, reach and

clearances shall be as shown in Fig.

5(b).

Figure 4a. Clear floor space.

Figure 4b. Forward approach.

Figure 4c. Parallel approach.

RL5000

XP

I

NsTaLLaTION

G

UIDE

4.2.4 Clear Floor or Ground

Space for Wheelchairs.

4.2.4.1 Size and Approach. The

minimum clear floor or ground space

required to accommodate a single,

stationary wheelchair and occupant

is 30 inches by 48 inches (760 mm by

1220 mm) (see Fig. 4a). The minimum

clear floor or ground space for wheel-

chairs may be positioned for forward

or parallel approach to an object (see

Fig. 4b and 4c). Clear floor or ground

space for wheelchairs may be part of

the knee space required under some

objects.