beautypg.com

Rl5000 – Triton RL5000XP PC-BASED ATMS Installation Manual User Manual

Page 30

background image

30

RL5000

XP

I

NsTaLLaTION

G

UIDE

PARTS SUPPLIED

4 Chemical Anchor

capsules (02316-00002)

4 Threaded chisel-point rods,

M12 x 1.75 (02302-00006)

8 Hex nuts, M12 x 1.75

(02301-00015)

4 Washers (02309-00014)

REQUIRED TOOLS/EQUIPMENT

1 Adjustable Crescent Wrench, or Ratchet Wrench with 18 mm

(3/4-inch) socket

1 Center Punch (for

marking drilling points)

1 Wire Brush (for cleaning

mounting holes)

1 Large Flat Screwdriver

1 Bubble Level

1

Heavy-Duty (Professional-

Grade) Electric Hammer

Drill.

1

6 mm (1/4-inch) and 15 mm

(9/16-inch) Carbide-tipped

Masonry Drill Bits - at least

15 cm (6-inches) long

1 Safety Goggles

1 Ear Plugs or Ear Muffs

(hearing protection)

1 Back-Support Belt

1

Portable Vacuum Cleaner or

Blower (to remove dust and

debris from mounting holes)

1. Carefully inspect the unit for

any shipping damage and report

any damage immediately to

the shipping company. Refer

to the warranty information

in the User or Service manual

(as applicable) for information

about reporting shipping

damage.

2. Remove the unit from the carton

by cutting the straps and removing

the top of the box.

SELECTING THE

INSTALLATION LOCA-

TION

Choosing the right location for

your ATM is very important.

Security concerns suggest a

location that is away from any

door or external access point.

Ideally, the terminal should

be mounted as close to a back

wall as possible. For marketing

reasons, however, it may be

desirable to locate the termi-

nal near the front where your

customers can easily locate it.

Wherever you decide to locate

the terminal, be sure to follow

the recommended procedures

for both mounting the terminal

and for removing cash when

the unit will be unattended.

UL LEVEL 1 CABINET

SAFETY

Level 1 cabinets are consider-

ably heavier than Business

Hours cabinets! Exercise ex-

treme caution when moving

Level 1 cabinets! At least two

persons should work together to

move the cabinet into position

for mounting!

UNPACK CASH DISPENSER

**IMPORTANT**

The RL5000

XP

is designed for

indoor installation only!

TOOL USE/SAFETY

Observe ALL safety precau-

tions for operating hand and

power tools! Wear eye and ear

protection while operating the

electric drill! USE A BACK-

SUPPORT BELT WHEN

LIFTING AND MOVING

THE ATM!

**IMPORTANT**

The following procedure applies to

the OPTIONAL Chemical anchor

install kit (06200-00060 - must

purchase)