TRITON SYSTEMS, INC.

SECTION 8 - ERROR RECOVERY

O

PERATION

M

ANUAL

- M

ODEL

97XX-Series

8-18

ERROR RECOVERY PROCEDURE

11

1.

Unlock an open the security container.

2.

Check the labels on the cassettes. If a duplicate cassette is
installed, replace it with the correct non-duplicate cassette. If
necessary, use the INJECT NEW CASSETTE ID procedure to
ensure each cassette has a unique ID (A, B, C, or D).

3.

Make sure all cassettes are IN SERVICE.

4.

RESET the cash dispenser and perform a Test Dispense. If
the dispense works, place the unit back in service.

5.

If the error occurs again, contact your service provider.

This Procedure applies to
the following error codes:

95