– Manually Close Curtain
Reference to Items in Figure 32 – Adjust Limit Switches
Item Description
Item Description
1
Switch HII
11
HI Setting Ring Screw
2 Switch
HI
12 Setting
Ring
3
Not Used
13
HI Setting Ring Screw
4
Terminal Rail
14
HII Setting Ring
5
Not Used
15
HII Setting Ring Screw
6
Not Used
16
HI Setting Ring
7
Not Used
17
HII Setting Ring Screw
8
Setting Ring
18
SII Setting Ring
9
SI Setting Ring Screw
19
SII Setting Ring
10
HI Setting Ring
20
Not Used
To set the Limit Switches, locate the Lock Motor Control Box.
See Figure 33. NOTE: Items noted in brackets [ ] in this
section can be found in Figure 32.
1. Unscrew the limit Switch Cover and
locate the Allen Wrench and the hex
shaft packaged in the Vinyl Storage Seal.
See Figure 34.
2. Remove the Vinyl Storage Seal and
locate the six Hex Adjusting Screws on
the Ring Screws. See Figure 35.
3. Run the curtains to the bottom position by using a Crank or
Drill [Item 14 Figure 31] or by manually turning the one of the
three Left Adjusting Screws with the Allen Wrench from the
Vinyl Seal as illustrated in Figure 35. NOTE: If turning the
drive with drill and adaptor, run to end position carefully (very
slowly). Maximum drive speed is 1400 rpm.
Limit Switch
Cover removed
Allen wrench
for adjusting
Limit Switches
Hex shaft for
manually
rotating motor
Vinyl
Storage
Seal
Figure 34
– Remove Limit Switch Cover
Lock Motor
Figure 33
– Lock Motor
Limit Switch
Cover
Curtain Moves Down