Hired-Hand Circulation and Stir Fans: MEGA FLOW Motor Replacement 36 (91 cm) Fan Housing User Manual
Warning, 36″ (91 cm) dairy fan housing, Before installing motor

HIRED-HAND MFG., INC.
• 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000
Manual Part No. 4801-5159
Page 1 of 2
Use a 12
point 3/8"
Socket
MOTOR REPLACEMENT INSTRUCTIONS
1. Disconnect all Electrical power to the Fan.
2. Remove the fan from its installation position and
place the fan on a level surface. Remove both the
front and rear Wire Guards. Save the hardware for
re-installation later.
3. Remove the power cable from the motor housing.
4. Position the fan with the blades facing upward.
5. Using a 12 point 3/8 socket, remove the fan blade.
See Figure 1.
1. Disconnect power source before installing or
servicing fan. Failure to disconnect power
source can result in property damage, serious
injury, or death.
2. When this fan is used in a life support ventilation
system where failure could result in loss or
injury, the user should provide adequate backup
ventilation, or accept the risk of such loss or
injury.
WARNING
!
M E G A F L O W
®
M o t o r R e p l a c e m e n t
36″ (91 cm) Dairy Fan Housing
1. Inspect motor for damage in transit. Check for
loose, missing, or damaged parts.
2. Do not operate fan until you are completely
familiar with its operation. READ ALL
INSTRUCTIONS PRIOR TO INSTALLATION.
Before Installing Motor
Post Mount
36" MegaFlow Fan using Ceiling Mount
Option
36" MegaFlow Fan with Post Mount
Option
Figure 1 – Remove the Fan
NOTE: Rear Guard removed
Crescent wrench
12 point 3/8" socket
3/8" Ratchet
2 1/4" Hole saw
7/16” Socket
9/32” Socket
9/32” Drill bit
Cordless drill
Tools Required
Description
Part No.
Motor
3017-3100
Replacement parts