Hired-Hand Funnel Flow Fans Rev 10-98 User Manual
Funnel flow, Panel fans
MAINTENANCE
2. Blades, motor and wire guards should be
cleaned periodically to decrease vibration and
ensure maximum fan life. Remove dirt with a dry
brush or compressed air.
Plastic Panel Fans Manual Part No. 4801-2991 Rev 10-98
Your Panel fan has been manufactured with the
finest materials and components available and is backed
by a one year warranty against electrical and mechanical
defects in material and workmanship. If this fan fails to
operate during this period, return it prepaid to place of
purchase for repair or replacement without charge at the
manufacturer's option.
Damage by accident or abuse is not covered by this
warranty.
This warranty gives you specific legal rights and you may
have other rights that vary from state to state.
WARRANTY
INSTALLATION
1.
Attach fan by flange to wall.
2. Fan is provided with wire guards for your protection.
National safety codes require that guards be installed
National safety codes require that guards be installed
if fan is installed within 7 feet of floor or
if fan is installed within 7 feet of floor or in reach of
in reach of
personnel or livestock.
personnel or livestock.
FAILURE TO GUARD MOVING PARTS MAY RESULT
IN SERIOUS INJURY OR DEATH.
3. Connect Power Cord and Electrical Power
4.
Unit is now ready for operation.
IMPORTANT: INSPECT FAN FOR ANY OBJECT
THAT MAY OBSTRUCT BLADE ROTATION.
REPLACEMENT PARTS
Part No. Description
6403-0121 SS FF 24" PROP 3 BLADE
3017-5018 Motor 1/3HP 1075RPM
1. Disconnect power source before installing or
servicing fan. Failure to disconnect power source
can result in property damage, serious injury, or
death.
2. When connected to an automatic controller
FAN MAY START AT ANY TIME.
3. When this fan is used in a life support ventilation
system where failure could result in loss or injury,
the user should provide adequate backup ventilation
or accept the risk of such loss or injury.
WARNING:
WARNING:
!!
1. Read WARNING statements before proceeding.
1. Inspect fan for damage in transit.
Check for loose, missing, or damaged
parts.
2. Do not operate fan until you are
completely familiar with its
operation.
BEFORE INSTALLING FAN
READ ALL INSTRUCTIONS PRIOR TO INSTALLATION
Funnel Flow
HIRED-HAND
®
Panel Fans
Panel Fans
®