beautypg.com

Hired-Hand Baffles, Vents, & Inlets: VENT DOORS Installation User Manual

Vent doors, Table a, Installation

background image

Hired-Hand Manufacturing, Inc.

• 1733 County Road 68 • Bremen, Alabama 35033 • PH 256-287-1000 • FAX 256-287-2000

Manual Part No. 4801-2975 Rev 10-06

Page 1 of 2









































TABLE A

Directions

1. Mark spacing of vent doors on wall.

2. Cut rough opening to size as shown in Table A above.

3. Vent door is supplied fully assembled. Bend handle up at

the positions marked with arrows in Figure 1A-B.

4. Insert vent door into hole with handle toward the top. (The

door should open from Top to Bottom, and to the inside of
the house).

5. Secure with screws through the twelve holes in each door.

Part

Number

Vent Size

Rough Opening

[email protected]" w.c.

(0.02 millibar)

[email protected]" w.c.

(0.04 millibar)

6609-0113 4.25”

x

45.75”

(10.78 cm x 116.21 cm)

4.5” x 46”

(11.43 cm x 116.84 cm)

716 CFM

(1216.5 m

3

/hr)

1000 CFM

(1699 m

3

/hr)

6609-0101 5.25”x44.25”

(13.33 cm x 112.4 cm)

5.5”x44.5”

(13.97 cm x 113.03 cm)

825 CFM

(1401.7 m

3

/hr)

1163 CFM

(1975.9 m

3

/hr)

6609-0112 5.25”x46.25”

(13.33 cm x 117.48 cm)

5.5”x46.5”

(13.97 cm x 118.11 cm)

864 CFM

(1467.9 m

3

/hr)

1218 CFM

(2069.4 m

3

/hr)

6609-0105

7” x 42”

(17.78 cm x 106.68 cm)

7.25” x 42.25”

(18.42 cm x 107.32 cm)

1045 CFM

(1775.5 m

3

/hr)

1478 CFM

(2511.1 m

3

/hr)

6609-0111

7” x 44”

(17.78 cm x 111.76 cm)

7.25” x 44.25”

(18.42 cm x 112.40 cm)

1097 CFM

(1863.8 m

3

/hr)

1551 CFM

(2635.1 m

3

/hr)

6609-0104

7” x 46”

(17.78 cm x 116.84 cm)

7.25” x 46.25”

(18.42 cm x 117.48 cm)

1148 CFM

(1950.5 m

3

/hr)

1624 CFM

(2759.2 m

3

/hr)

6609-0125

7” x 55”

(17.78 cm x 139.70 cm)

7.25” x 55.25”

(18.42 cm x 140.34 cm)

1400 CFM

(2378.6 m

3

/hr)

2000 CFM

(3398 m

3

/hr)

6609-0134

8” x 43.5”

(20.32 cm x 110.49 cm)

8.25” x 43.75”

(20.96 cm x 111.13 cm)

1522.5 CFM

(2586.7 m

3

/hr)

2066 CFM

(3510.2 m

3

/hr)

6609-0102

8” x 44”

(20.32 cm x 111.76 cm)

8.25” x 44.25”

(20.96 cm x 112.40 cm)

1296 CFM

(2201.9 m

3

/hr)

1833 CFM

(3114.3 m

3

/hr)

6609-1001

8” x 46”

(20.32 cm x 116.84 cm)

8.25” x 46.25”

(20.96 cm x 117.48 cm)

1380 CFM

(2344.6 m

3

/hr)

1870 CFM

(3177.2 m

3

/hr)

6609-0120

8” x 71.50”

(20.32 cm x 127.00 cm)

8.25” x 71.75”

(20.96 cm x 182.25 cm)

2000 CFM

(3398 m

3

/hr)

2950 CFM

(5012.1 m

3

/hr)

6609-0132 9.75”

x

60.75”

(24.77 cm x 154.31 cm)

10” x 61”

(25.40 cm x 154.94 cm)

2180 CFM

(3703.8 m

3

/hr)

3090 CFM

(5249.9 m

3

/hr)

6609-1044 10”

x

44”

(25.40 cm x111.76 cm)

10.25” x 44.25”

(25.40 cm x 154.94 cm)

1620 CFM

(2752.4 m

3

/hr)

2250 CFM

(3822.77 m

3

/hr)

6609-0128 10”

x

48”

(25.40 cm x 121.92 cm)

10.25” x 48.25”

(26.04 cm x 122.56 cm)

1800 CFM

(3058.2 m

3

/hr)

2500 CFM

(4247.5 m

3

/hr)

6609-1050 10”

x

52”

(25.40 cm x 132.08 cm)

10.25” x 52.25”

(26.04 cm x 132.72 cm)

1900 CFM

(3228 m

3

/hr)

2780 CFM

(4723.5 m

3

/hr)

6609-0129 10”

x

56”

(25.40 cm x 142.24 cm)

10.25” x 56.25”

(26.04 cm x 142.88 cm)

2050 CFM

(3483 m

3

/hr)

3000 CFM

(5097 m

3

/hr)

6609-0130 10.25”

x

47.75”

(26.04 cm x 121.29 cm)

10.5” x 48”

(26.67 cm x 121.92 cm)

1800 CFM

(3058.2 m

3

/hr)

2500 CFM

(4247.5 m

3

/hr)

6609-0131 11.75”

x

47.75”

(29.85 cm x 121.29 cm)

12” x 48”

(30.48 cm x 121.92 cm)

2050 CFM

(3483 m

3

/hr)

3000 CFM

(5097 m

3

/hr)

6609-0133

11.75” X 60.75”

(29.85 cm x 154.31 cm)

12” x 61”

(30.48 cm x 154.94 cm)

2700 CFM

(4587.3 m

3

/hr)

3800 CFM

(6456.2 m

3

/hr)

6609-1060

12” X 46”

(30.48 cm x 116.84 cm)

12.25” x 46.25”

(31.12 cm x 117.45 cm)

2000 CFM

(3398 m

3

/hr)

2940 CFM

(4995 m

3

/hr)

VENT DOORS

Installation

Figure 1

Flat metal
handle

Bend handle out 90

°

at perforation

NOTE: Handle contains hole
for cable attachment.

A

B

Tools Required

12-1" (2.54 cm) Wood Screws

Screw Driver

Pop Rivet Gun

Saws

A