Hired-Hand RollSeal Sidewall System (Curtain): SideWall Curtain User Manual
Page 14
Part No. 4801-5072 Rev 9-08
Side Wall Curtain
Page 14
Motor Cable Positioning
Depending on the application, the motor cable
can pass through the center of side of the motor
head. Raise yellow cover plate, reposition the
cable, and then press cover place into position.
Mounting The Motorized Tube
The motor brackets are equipped with a clip ring.
This clip ring does not have to be removed for
installation. You can press the motor axially into the
motor bracket in any of six positions, so that the limit
switch adjustment buttons are always easily
accessible.
1. Before sliding motor into drive
pipe, measure distance from end
of motor to end of motor tube.
This distance is labeled as R in
Fig. 11b.
2. Slide the tubular motor into the
slotted end of the drive pipe until
the raised key of the motor- head
seats into the slot.
(See Fig. 11a).
3. As shown in Fig. 11b. Drill
several 3/16 in. (0.48 cm) holes
around the circumference of pipe
at distance R (measured in step
1). Install stainless steel pop
rivets into the holes to fasten
motor tube.
Raised Key
Tube Notch
R
FIGURE 11
a
b
8.9.2 Somfy Motor Attachment To Drive Pipe
8.9.3 Installation Of Drive Pipe
Refer to Section 8.11 for instructions on placing drive pipe
into guide brackets. Refer to section 8.9.4 after installing
drive pipe.
8.9.4 Somfy Motor Connection To Motor Mount
(IMPORTANT! FIRST INSTALL DRIVE PIPE TO SYSTEM. SEE SECTION 8.11)
Lift end of drive pipe containing the motor, and attach the motor to the motor bracket which is installed on the
motor mount. Press motor into the bracket as shown in Figure 12. Be sure the limit switches are accessible.
CAUTION!
Do Not Drill Into Motor
When Installing Pop Rivets
Figure 12