Hired-Hand RollSeal Sidewall System (Curtain): SideWall Curtain User Manual
Page 16
Part No. 4801-5072 Rev 9-08
Side Wall Curtain
Page 16
NOTE: Set Limit Switches After Curtain Is Installed.
8.9.6 Somfy Motor Limit Switches
The UP position & DOWN position have to be set.
This is where the sidewall curtain will automatically
stop.
1.
Ensure the power switch is in the OFF position.
2.
Remove the protective cap from the motor
head. Depress fully both limit switch push
buttons (if not already pushed). They will
automatically lock in the down position.
3.
Turn on the power switch and check that the
system operates correctly. If not, put the
switch in the OFF position, disconnect all
power sources, and reverse the black and
red motor connection wires.
4.
Stop Position 1
Bring motor rotation into desired stop position 1
(Note direction of rotation differs whether motor
is left or right mounted).
Turn off power switch when position is reached.
Unlock the UP limit switch push button by
depressing and releasing it. This sets the
UP limit.
Stop Position 2
Repeat the above operation to set the lower
limit.
5.
Check with the switch that the motor stops
at the up & down positions just set.
6.
Refit the protective cap.
7.
Allow the motor to run in both directions,
until it shuts off in the stop positions. Because
of the built in thermal protection feature, the
motor may shut off automatically after running
without interruption for an extended period of
time. Please wait until the motor has cooled off
and is ready for operation again, (approximately
10-15 minutes).
Changing the Set Stop Position
Press the limit switch adjustment button that
lies in the direction of rotation. Bring the
curtain into the desired stop position.
Release the limit switch adjustment button by
pressing it down again.
Figure 14
UP
Stop Position 1
DOWN
Stop Position 2
Stop Position 1
Depending Upon Type Of Installation
Motor On Left
Motor On Right
Stop Position 2
Depending Upon Type Of Installation
Motor On Left
Motor On Right