52
Brocade MLX Series and NetIron Family Documentation Updates
53-1003301-07
10Gx24-port interface module
4
Brocade MLX Series and Brocade NetIron XMR
The following table note is added to the “blinking” state of the switch fabric module LED in the
Product Overview chapter of the Brocade MLX Series and Brocade NetIron XMR Series Hardware
Installation Guide.
10Gx24-port interface module
For maximum performance, you will need to change the system-init tm-credit-size to credit_1024b.
Log into your system and enter the following commands in the configuration level of the CLI. It is
important to issue commands to write memory and reload the device.
Brocade# config
Brocade(config)# system-init tm-credit-size credit_1024b
Brocade(config)# exit
Brocade# write memory
Brocade# reload
MLX 48x1G-T interface module
In prior releases the MLX 48x1G-T module was listed as GEN1 module. As of NetIron 5.6.00c the
MLX 48x1G-T module is listed as a GEN1.1 module.
TABLE 2
Switch fabric module LEDs
LED
Position
State
Meaning
Pwr
Above Active LED
On
The module is receiving power.
Off
The module is not receiving power.
Active
Below Pwr LED
On
(4-, 8-, and 16-slot
routers only)
The switch fabric is on (active) and ready to switch
user packets.
On
(32-slot routers only)
The switch fabric is on (active) and ready to switch
user packets.
Blinking
(32-slot routers only)
The switch fabric is on (active) and being accessed by
the Management Module CPU. This indicates normal
operation.
NOTE: On devices supporting software version
R05.3.00 and earlier, when you insert an SFM
or during powering on the device, the Active
LED was off for a short duration, up to 15
seconds because the monitoring of the Fabric
module is stopped for this duration. After this
delay, the LED indicated the monitoring status.
In version R05.4.00 and later, the Active LED
reads the switch fabric continuously even
during module insertion or powering on the
device, and thus the Active LED blinks.
Off for extended
period
The switch fabric is not active and cannot switch user
packets.