52

Brocade MLX Series and NetIron Family Documentation Updates

53-1003301-07

10Gx24-port interface module

4

Brocade MLX Series and Brocade NetIron XMR

The following table note is added to the “blinking” state of the switch fabric module LED in the
Product Overview chapter of the Brocade MLX Series and Brocade NetIron XMR Series Hardware
Installation Guide.

10Gx24-port interface module

For maximum performance, you will need to change the system-init tm-credit-size to credit_1024b.
Log into your system and enter the following commands in the configuration level of the CLI. It is
important to issue commands to write memory and reload the device.

Brocade# config

Brocade(config)# system-init tm-credit-size credit_1024b

Brocade(config)# exit

Brocade# write memory

Brocade# reload

MLX 48x1G-T interface module

In prior releases the MLX 48x1G-T module was listed as GEN1 module. As of NetIron 5.6.00c the
MLX 48x1G-T module is listed as a GEN1.1 module.

TABLE 2

Switch fabric module LEDs

LED

Position

State

Meaning

Pwr

Above Active LED

On

The module is receiving power.

Off

The module is not receiving power.

Active

Below Pwr LED

On
(4-, 8-, and 16-slot
routers only)

The switch fabric is on (active) and ready to switch
user packets.

On
(32-slot routers only)

The switch fabric is on (active) and ready to switch
user packets.

Blinking
(32-slot routers only)

The switch fabric is on (active) and being accessed by
the Management Module CPU. This indicates normal
operation.
NOTE: On devices supporting software version

R05.3.00 and earlier, when you insert an SFM
or during powering on the device, the Active
LED was off for a short duration, up to 15
seconds because the monitoring of the Fabric
module is stopped for this duration. After this
delay, the LED indicated the monitoring status.
In version R05.4.00 and later, the Active LED
reads the switch fabric continuously even
during module insertion or powering on the
device, and thus the Active LED blinks.

Off for extended
period

The switch fabric is not active and cannot switch user
packets.