TM XPP link status check
1
TM XPP link status check
The link between TM and XPP is periodically monitored to determine link issues at run time and
perform appropriate recovery.
Brocade(config)#sysmon tm nif-check threshold
count
120
Brocade(config)#sysmon tm nif-check disable-ports
Syntax: [no] sysmon tm nif-check threshold count polling period
Syntax: [no] sysmon tm nif-check action
disable-ports ports disable for nif errors
reset-linecard linecard reset for nif errors
Examples
Default action:
Syslog:Mar 4 20:33:57:A:System: LP15/TM0: All ports down due to TM XPP link
down
Mar 4 20:33:57:I:System: Interface ethernet 15/4, state down - TM XPP link
down
Mar 4 20:33:57:I:System: Interface ethernet 15/3, state down - TM XPP link
down
Mar 4 20:33:57:I:System: Interface ethernet 15/2, state down - TM XPP link
down
Mar 4 20:33:57:I:System: Interface ethernet 15/1, state down - TM XPP link
down
Snmp trap:
Health Monitoring: LP15: All ports down due to TM XPP link down
Line card reset action:
Syslog:
Mar 4 20:33:57: D:System: Module reset in slot 1, triggered by TM Health
Monitoring
Mar 4 20:33:57: D:System: TM Health Monitoring detects an issue in slot 1 ppcr 1
TM XPP link down
Snmp trap:
Type- debugging