beautypg.com

Separate threshold for crc logging, Examples, Cli for sfm and internal fe – Brocade MLX Series and NetIron Family (Supporting Multi-Service IronWare R05.6.xx) User Manual

Page 36: Example, Tm ras enhancements

background image

28

Brocade MLX Series and NetIron Family Documentation Updates

53-1003301-07

TM RAS Enhancements

1

Separate Threshold for CRC logging

Brocade(config)#sysmon tm link crc-logging threshold

Syntax: sysmon tm link crc-logging threshold count

For action:

syntax - sysmon tm link crc-logging action

none - No action

tmlog - tm logging

syslog - Generate a syslog

Examples

Syslog

Mar 4 20:33:57: I:System: Health Monitoring: TM Link CRC errors: SFM5/FE 1/ Link16

-> LP 15/TM 1/link4

TM log

Mar 4 20:33:57: TM Link CRC errors: SNM5/FE1/Link16 -> LP15/TM1/Link4

CLI for SFM and Internal FE

Brocade(config)#sysmon felink crc-logging threshold

Syntax: sysmon fe link crc-logging threshold count

Syntax: sysmon fe link crc-logging threshold action

For action:

none - No action

sfmlog - sfm logging

syslog - Generate a syslog

Example

Syslog

Mar 4 20:33:57: I:System: Health Monitoring: Fabric Link CRC errors:

LP15/TM1/Link4 -> SNM5/FE1/Link16

For Internal FE linecards such as 2x100G and 24x10G

Mar 4 20:33:57: I:System: Health Monitoring: Fabric Link CRC errors:

LP15/FE1/Link4 -> SNM5/FE1/Link16

SFM log

Mar 4 20:33:57: Fabric Link CRC errors: LP15/TM1/Link4 -> SNM5/FE1/Link16

Mar 4 20:33:57: Fabric Link CRC errors: LP15/FE1/Link4 -> SNM5/FE1/Link16