Lp auto-upgrade, Scp “success message – Brocade MLX Series and NetIron Family (Supporting Multi-Service IronWare R05.6.xx) User Manual
Page 38

30
Brocade MLX Series and NetIron Family Documentation Updates
53-1003301-07
LP auto-upgrade
1
Brocade NetIron CER and Brocade NetIron CES single-command
(full-system) upgrade
NOTE
BOOT images are not included in the upgrade process. The optional keyword “all-images” specifies
to include only the MP FPGA images (MBRIDGE/MBRIDGE32 and SBRIDGE/HSBRIDGE).
Syntax: copy tftp system [all-images]
LP auto-upgrade
LP Auto-upgrade does a manifest file integrity check with signatures.
NOTE
LP auto-upgrade is not supported in FIPS mode.
File integrity checks rely on the correct signatures being present on the system at the time of the
check, based on the currently running version of the device.
Refer to the Federal Information Processing Standards and Common Criteria Guide for NetIron
5.6.00 for more information when upgrading from non-SHA256 signatures to SHA256 signature
packages or downgrading from SHA256 signature to non-SHA256 signature packages.
When downgrading from SHA256 signed packages to SHA1 signed packages following errors might
be seen:
TFTP: Download to flash done.
TFTP: Download to flash failed - Server Message: File not found
Failed to rename manifest_tmp.sig into manifest.sig
NOTE
If this is a downgrade to 5.6B or earlier, the above errors may be ignored.
SCP “success message”
The following update goes in “Configuring Secure Shell and Secure Copy” chapter, under “Using
Secure Copy” section.
NOTE
The scp command will not display any “success message” on completion of data transfer. Instead
use showlog command to validate scp image success.