Supported port configurations for each application, Flow frametype parameters – Brocade Flow Vision Administrators Guide (Supporting Fabric OS v7.3.0) User Manual
Page 19

Supported port configurations for each application
The following table lists the supported configurations for each Flow Vision feature that can be made
using only the basic flow identification parameters (ingrport and srcdev, egrport and dstdev).
Port configurations supported in Flow Vision
TABLE 4
Feature
Platforms
Switch Configuration Mode
16 Gbps-capable Fibre Channel
(Gen 5)
8 Gbps-capable Fibre
Channel
Access Gateway
Virtual Fabric
Flow
Generator
Supported (SIM ports only)
Supported (Destination
SIM ports only)
Not Supported
Supported
Flow
Mirror
Supported (F_Ports and F_Port
trunks)
Not Supported
Not Supported
Supported
Flow
Monitor
Supported (E_Ports, EX_Ports,
F_Ports, SIM ports, and
XISL_Ports)
Supported (E_Ports,
EX_Ports, F_Ports, and
XISL_Ports)
Supported
(F_Ports only)
Supported
Notes on supported configurations
• Neither ranges nor lists are supported for any parameter.
• If you are using at least one advanced parameter (lun, frametype, or bidir), then feature-specific rules
apply. Refer to the individual Flow Vision features for specific details.
• Support for Gen 5 F_Ports and F_Port trunks is provided on the following devices:
‐
Switches: Brocade 6505, 6510, 6520, DCX 8510-4 and DCX 8510-8
‐
Blades: CR16-4, CR16-8, FC8-32E, FC8-48E, FC16-32, FC16-48, and FC16-64
‐
Disabling a SIM port that is receiving traffic may produce class 3 discards for the simulated
traffic; however, this will have no effect on other traffic flows.
Flow frametype parameters
Frame monitoring can be done for a variety of frames using predefined frametype parameters.
The following table lists these parameters and the type of frames counted for each.
Supported frametype parameters
TABLE 5
Frametype
parameter
Frames counted
abts
Abort Sequence
baacc
All frames accepted
barjt
All frames rejected
scsi
All SCSI frames (including both command and data frames)
scsiread
Only SCSI read command frames
Supported port configurations for each application
Flow Vision Administrators Guide
19