Hardware maintenance and replacement, Hardware maintenance schedule, Copper or fiber-optic module replacement – Brocade ICX 6450 Stackable Switches Hardware Installation Guide User Manual
Page 85: Removing a copper or fiber-optic module
Hardware Maintenance and Replacement
Hardware maintenance schedule
DANGER
The procedures in this manual are for qualified service personnel.
The ICX 6430 and ICX 6450 devices require minimal maintenance for their hardware components.
However, Brocade recommends cleaning the fiber-optic connectors on a fiber-optic port and the
connected fiber cable each time you disconnect the cable.
Copper or fiber-optic module replacement
You can replace the copper and fiber-optic modules (SFP transceivers). You can remove an SFP
transceiver from a slot and replace it with a new one while the ICX 6430 or ICX 6450 device is powered
on and running.
This section provides information about the following tasks:
•
Removing a copper or fiber-optic module
•
Installing a new copper or fiber-optic transceiver
•
Cabling a fiber-optic module
•
Cleaning a fiber-optic module
Removing a copper or fiber-optic module
You can remove a copper or fiber SFP transceiver from a slot while the ICX 6430 or ICX 6450 device is
powered on and running.
While removing a copper or fiber-optic module, be sure to wear an ESD wrist strap with a plug that can
be inserted in the ESD connector on the ICX 6430 or ICX 6450 device.
DANGER
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.
To remove a copper or fiber-optic module from an SFP slot, do the following.
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide
83
53-1003079-01