beautypg.com

Brocade ICX 6450 Stackable Switches Hardware Installation Guide User Manual

Page 21

background image

1

System status LEDs

FIGURE 17 System status LEDs on ICX 6430-48P 48-port model

System status LEDs on ICX 6450 and ICX 6430 devices

TABLE 3

LED

Condition

Status

EPS1 and EPS2

(External Power Supply status for ICX
6450_48P devices only)

Green

EPS1 and EPS2 power supplies are operating
normally.

Yellow

EPS1 and EPS2 power supply fault.

Off

EPS1 and EPS2 off or not present.

PWR

(Power)

Green

Power supply is operating normally.

Yellow

Power supply fault.

Off

Power supply off.

Diag

(Diagnostic)

Flashing Green System self-diagnostic test in progress. System

reloads automatically.

Steady Yellow

System self-diagnostic test has detected a fault. (Fan,
thermal, or any interface fault.) The user must reload
the system.

MS

(Stacking configuration)

Green

The device is the Active controller. Flashing indicates
the system is initializing.

Yellow

Indicates the device is the Standby controller. Flashing
indicates the system is in Master arbitration or
selection state.

Off

Device is operating as a stack member, or is in
standalone mode.

Uplink (X1 and X2)

(Stacking port status)

Green

Uplink port is operating normally.

Off

Uplink has failed or there is no link.