Setting the “Indicator-out” Mode and Locking Parameters
Parameter Setting Types and Ranges
Display setting menu
Indicator-out mode
Indicator-out mode wait time
Selection
Integral
numeric
value
ON
OFF
1 to 60 (min)
OFF
10 (min)
Menu to shift to the parameters of
display setting
Parameter Symbol
Parameter Name
Setting
Type
Setting Range (Details)
Initial Value
(Factory-set
Value)
Indicator-out mode
The indicator-out mode is designed to turn off the PR300 display when no key operation is performed
within the indicator-out mode wait time that has been set while measured values are on display. The
PR300 switches to the Measured Value screen in about 5 minutes when no key operation is performed
while the Parameter screen is on display. Then, the PR300 display turns off after the elapse of the
indicator-out mode wait time from when the PR300 switched to the Measured Value screen.
To turn on the PR300 display to show measured values during indicator-out mode, press any key.
Locking and Unlocking Parameters
Executing the following operations locks or unlocks all parameters. (A parameter cannot be locked or
unlocked individually.) If a parameter is locked, it will be impossible to shift to the Parameter Setting screen.
Use the Parameter screen showing the current value or the Menu screen to lock or unlock parameters.
Operations used on an individual parameter setting screen or on the Measured Value screen in an attempt to
lock parameters will have no effect.
Operation
Operation
Operation
Operation
The measured value display
(middle display) first shows
, then returns to the
Parameter screen.
VT Ratio screen
2
All parameters are locked now.
Pressing will no longer
switch the display to any
parameter setting screen.
The measured value display
(middle display) first shows
, then returns to the
Parameter screen.
All parameters are unlocked
now.
Simultaneously hold
down and
for at least 5
seconds.
Measured Value screen
1
Measured Value screen
1
The parameter (VT ratio)
appears.
VT Ratio screen
2
Simultaneously hold
down and
for at least 5
seconds.
The parameter (VT ratio)
appears.
Hold down for at
least 3 seconds.
Hold down for at
least 3 seconds.
Unlocking Parameters