Model
Suffix Code
Description
MX110
Input type
-UNV
For DCV/TC/DI/3-wire RTD input
-VTD
For DCV/TC/DI input
-V4R
For DCV/DI/4-wire RTD/4-wire resistance input
Number of channels and
measurement interval
-H04
*1
4-CH, high-speed measurement (minimum measurement Interval: 10 ms)
-M06
*1
6-CH, medium-speed measurement (minimum measurement interval: 100 ms)
-M10
*1
10-CH, medium-speed measurement (minimum measurement interval: 100 ms)
-L30
*1
30-CH, medium-speed measurement (minimum measurement interval: 500 ms)
Options
/NC
*2
Without the plate with the clamp terminals
/H3
*3
M3 screw terminals
*1 “-H04” or “-M10” must be selected if “-UNV” is selected. “-M06” must be selected if “-V4R” is selected. “-VTD” must be
selected if “-L30” is selected.
*2 The “/NC” option can be specified only when “-M10” is specified.
*3 The “/H3” option can be specified only when “-L30” is specified.
Strain Input Module
Model
Suffix Code
Description
MX112
Input type
-B12
Internal bridge resistance: 120 Ω
-B35
Internal bridge resistance: 350 Ω
-NDI
NDIS connector for connections to an external bridge head
Number of channels and
measurement interval
-M04
4-CH, medium-speed measurement (minimum measurement and
measurement interval: 100 ms)
Pulse Input Module
Model
Suffix Code
Description
MX114
Input type
-PLS
Non-voltage contact, 5-V logic, open collector input
Number of channels and
measurement interval
-M10
10-CH, medium-speed measurement (minimum measurement interval: 100 ms)
Options
/NC
Without the plate with the clamp terminals
Digital Input Module
Model
Suffix Code
Description
MX115
Input type
-D05
Non-voltage contact, 5-V logic, open collector input
-D24
24 V logic input
Number of channels and
measurement interval
-H10
10-CH, high-speed measurement (minimum measurement and measurement
interval: 10 ms)
Options
/NC
Without the plate with the clamp terminals
Analog Output Module
Model
Suffix Code
Description
MX120
Output type
-VAO
Voltage/current output
-PWM
Pulse width modulation output
Number of channels and
output update interval
-M08
8-CH, minimum output update interval: 100 ms
Digital Output Module
Model
Suffix Code
Description
MX125
Output type
-MKC
A contact output
Number of channels and
output update interval
-M10
10-CH, minimum output update interval: 100 ms