<5. Parameter Summary>

5-7

IM 01C25R02-01E

Function

Label

Item

Contents

Default value Handling

*

1

Master test

Master test

Software reset and self test

M

Message

Message

Message

32 alphanumerics

As specified

W

Model

Model

Model

W

Number of

requested

preambles

Num req preams

Number of requested preambles

R

Num resp preams

HART 7

Number of response preambles

5

W

Optional

function

Option Password

Optional function activation

password

W

Piping

orientation

H/L Swap

Impulse piping accessing direction Normal or Reverse

Normal

R

Poll address

Poll addr

Poll address for multidrop use

0 to 15(HART 5), 0 to

63(HART 7)

0

W

Loop current mode

HART 7

Loop current mode in Multi Drop

mode

(Disabled, Enabled)

Disabled

W

Process Alerts Digital Output

Display of contact output

Off or On

Off

W

DO Frequency

Frequency of Digtal Output

W

DO Select

Contact output select

Combination of Pres, SP,

Temp, and Flow

W

DO Signal type

Signal type select

On When Al. Detect, Off

When Al. Detect, Scaled

Pulse, or Frequency

W

DO Test

Test output contact

Status High, Status Low,

Freguency, Exit

M

Test Auto Release

Time

“Flow simulation”, “DO Test”,

“Device Variable Simulation”

and “Test output” duration time

selection.

10min, 30min, 60min, 3h,

6h, 12h

10min

W

Pres Alert Mode

Alert Mode for differential pressure Off, Hi Al Detect,Lo Al Detect,

Hi/Lo Al Detect

Off

W

Pres Hi Alert Val

High alert value for differential

pressure

Set the threshold value for

high side alarm

W

Pres Lo Alert Val

Low alert value for differential

pressure

Set the threshold value for

low side alarm

W

SP Alert Mode

Alert Mode for static pressure

Off, Hi Al Detect,Lo Al Detect,

Hi/Lo Al Detect

Off

W

SP Hi Alert Val

High alert value for static pressure

Set the threshold value for

high side alarm

W

SP Lo Alert Val

Low alert value for static pressure

Set the threshold value for

low side alarm

W

ET Alert Mode

Alert Mode for external temperature Off, Hi Al Detect,Lo Al Detect,

Hi/Lo Al Detect

Off

W

ET Hi Alert Val

High alert value for external

temperature

Set the threshold value for

high side alarm

W

ET Lo Alert Val

Low alert value for external

temperature

Set the threshold value for

low side alarm

W

Flow Alert Mode

Alert Mode for flow

Off, Hi Al Detect,Lo Al Detect,

Hi/Lo Al Detect

Off

W

Flow Hi Alert Val

High alert value for flow

Set the threshold value for

high side alarm

W

Flow Lo Alert Val

Low alert value for flow

Set the threshold value for

low side alarm

W

Process

variables

Change 4V Assgn

HART 5

Change the allocation to 4V

M

4V

HART 5

4V value

Unit specified in 4V Unit

R

4V is

HART 5

Current 4V

R

Amp temp

Amplifier temperature

R

Cap temp

Capsule temperature

R

Engr Disp

User scaled value

Unit specified in Set Engr Unit

R

*1: Handling: R-Read only, W-Read & Write, M-Method, G-Applicable for option code DG6

*2: Max three Burst Messages (Burst Message 1, Burst Message 2, Burst Message 3)